65
FIG. 74
System Security Settings
WebConsole - Security Options
Security - General
The General Security Settings page provides global permissions for various options that may be individually selected and applied
to all users. The Master provides 3 levels of security settings presets: Low, Medium, and High. The levels are simply presets of
various security settings. When a preset is selected, the settings are not applied until you click
Accept
. You can customize any
settings as needed on the security preset before accepting and applying the settings. The default for the settings will match the
Low presets.
System Level Security - System Security Settings
Click the
System Security Settings
link to access the System Security Details page (FIG. 74). The options in this page allow
you to establish whether the Master will require a valid user name and password be entered prior to gaining access to the config-
uration options.
These are global options that enable or disable the login requirement for both users and roles.
System Security Options
The System Security options are described in the following table:
Instruction Manual - Incite Digital Video Presentation Systems
System Security Options
Option
Description
Security Presets
The Master provides three levels of security setting presets: Low, Medium, and High. Each level is a preset
of various security settings (see the Security Presets section on page 68 for more information.) When a
preset is selected, that setting is applied after clicking Accept.
NOTE:
If a security preset is not selected, all subordinate options are grayed-out and not selectable, mean-
ing that the Master is completely unsecured and can be altered by any user (regardless of their rights).
Audit Log
Select to enable/disable remote syslog. See the Audit Logs section on page 68 for more information.
Banner Display
Select to turn on or turn off banner messages. Banners enable you to display pre- and post-login text in
the WebConsole.
See the Banners section on page 69 for more information.
USB Host Port
Select to enable all Type-A USB connectors on the Master.