Connecting the MXA-MPL to a Network

Since the MXA-MPL works to transmit HD video and images from an Enova switcher to a

Modero X touch panel, it needs to be connected between the switcher and the touch

panel. To connect the touch panel to the MXA-MPL:
1.

Insert the incoming network connection cable from the Enova switcher to the

upper 

Ethernet In

 RJ-45 connector (FIG. 1).

2.

If the touch panel is MXD/T-1000/1001, MXD/T-700/701, MXD-430/431),

connect an outgoing Ethernet cable from the MXA-MPL’s 

Ethernet Out

 RJ-45

connector to an AMX-certified high-power Power over Ethernet injector. Do not

apply power until the installation is complete.

• For PoE-powered Modero X touch panels, the AMX-certified PoE injector must be

connected between the MXA-MPL and the touch panel. Use of a PoE switch in

place of an AMX-certified PoE injector is NOT recommended.

3.

If the touch panel is a MXD/T-1900/1901L-PAN or MXD/T-2000/2001XL-PAN,

outgoing power to the touch panel may be supplied via the MXA-MPL’s 2-pin

+12V Power output (FIG. 1) or through another source. Do not apply power until

the installation is complete.

Note:

 

If using the MXA-MPL’s 2-pin connector for power for a touch panel, please refer to 

Maximum Power Cable Gauges and Distances

section

 below for maximum cable 

lengths between the MXA-MPL and the touch panel, based on cable gauge. Using a 

separate power source for 19/20” panel installations that require long cable runs is 

highly recommended.

4.

When the installation is complete, apply power to the MXA-MPL and to the touch

panel. Verify via the LEDs on the front of the device that it is receiving power and

is connected to the network.

5.

If the touch panel has not been configured to receive video signals from the MXA-

MPL, do so now.

FIG. 5 provides a basic installation diagram for the MXA-MPL: 

Maximum Power Cable Gauges and Distances

While most Modero X Series touch panels use Power Over Ethernet (PoE) for their

power needs, the 19/20” Modero X Series touch panels use external power from an

AMX-certified power source. 
The MXA-MPL may be used as a power source for the panoramic touch panels, but only

to certain lengths determined by the cable gauge and the max distance between the

device and the touch panel. 

Note:

 All power cable gauges are in AWG (American Wire Gauge).

When installing panoramic Modero X Series touch panels that exceed these cable

lengths between the MXA-MP/MPL and the touch panel, a separate AMX-certified power

source should be used instead.

Configuring the MXA-MPL

After the MXA-MPL is connected to the network, the touch panel to which it is

connected needs to be configured to receive its signals. Configuring the MXA-MPL into

a network requires modification of the device’s corresponding NetLinx files via NetLinx

Studio and the associated touch panel pages via TPDesign 4. Documentation of the

available commands may be found in the 

Modero X Series Programming Guide

, available

at 

www.amx.com

.

To configure the touch panel:
1.

From the 

Settings

 page, select 

Connections & Networks

.

2.

From the 

Connections & Networks

 page, select 

Breakout Box

 to open the 

Breakout

Box

 page (FIG. 6).

3.

Press the 

Breakout Box

 button to enable the panel to receive information from

the MXA-MPL. 

4.

If the MXA-MPL is connected, the remaining information on the Breakout Box

page will self-populate.

Note:

 If the MXA-MPL is not connected to the touch panel, any attempts at enabling the 

panel will fail, and the Breakout Box page will be blank other than the Breakout Box 

button.

Rebooting the MXA-MPL

To reboot the MXA-MPL, press and hold the 

Reset

 button (FIG. 1) for one second.

Resetting the MXA-MPL to Factory Defaults

To reset the MXA-MPL’s configuration settings to its factory defaults:

1.

Press and hold the 

Factory Reset 

button (on the front panel) for about 5 seconds.

2.

The 

Power

 LED will blink three times. At this time, release the 

Factory Reset

button. 

To reset the MXA-MPL’s firmware from its current version to its factory default version:

1.

Press and hold the 

Factory Reset

 button (on the front panel) for about 10

seconds. 

2.

At about the 5-second mark, the 

Power

 LED will blink 3 times. Keep holding the

Factory Reset 

button. At the 10-second mark, the Power LED will blink 7 times at

a faster rate. At this time, release the Factory Reset button.

FIG. 5  

INSTALLATION DIAGRAM - MXA-MP AND MXA-MPL

MAXIMUM POWER CABLE GAUGES AND DISTANCES

Cable Gauge 

(AWG)

Maximum Distance (feet/meters)

<16

Not recommended

16

24 feet (7.32 meters)

17

20 feet (6.10 meters)

18

15 feet (4.57 meters)

19

12 feet (3.66 meters)

20

10 feet (3.05 meters)

21

8 feet (2.44 meters)

22

6 feet (1.83 meters)

23

5 feet (1.52 meters)

24

4 feet (1.22 meters)

>24

Not recommended