6.

Carefully connect the ribbon cable to the DAS-MNET. 

Note

: When the 20-pin connector on the ribbon cable is positioned prop-

erly, it should snap into the connector on the DAS-MNET without undue 
force. To avoid damage to the ribbon cable and/or DAS-MNET card, do 
not force the connector into place.
Be sure that both ends of the cable are securely plugged into their 
respective boards through the 20-pin connectors. 

7.

Replace the unit cover and apply power to the Controller.

Mi-Series LCD Display

Once the DAS-MNET has been installed and power has been applied to the 
Mi-Series Controller, additional information is available via the LCD display on 
the front panel of the Mi-Series controller.
To access the DAS-MNET information on the front LCD display:
1.

With the AMX logo displayed on the Mi Series LCD display, press the 
Select button to access the Main Menu.

2.

Press the Left arrow button to scroll to the About menu item. Press Select 
to access the About menu.

3.

Press the Left arrow button to scroll to the NIC menu item. Press Select to 
access the NIC menu, which displays the following information specific to 
the DAS-MNET card:

• The version of NIC card firmware currently loaded on the DAS-MNET is 

indicated in parenthesis, after the phrase “Network Interface Card”.

• The IP Address currently assigned to the DAS-MNET.
• DHCP status (Enabled or Disabled).
• Select “OK” to return to the previous menu.

Ethernet Port and LED Indicators 

The Ethernet port on the DAS-MNET uses two LEDs to indicate status and 
activity, as described below (FIG. 6): 

Ethernet Port

RJ-45 port for 10/100 Mbps communication. The Ethernet Port automatically 
negotiates the connection speed (10 Mbps or 100 Mbps) and whether to use 
half duplex or full duplex mode.

Ethernet Link/Activity LEDs

Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show 
communication activity, connection status, speeds, and mode information:

• SPD (speed) - Green LED lights On when the connection speed is 100 

Mbps and turns Off when the speed is 10 Mbps.

• L/A (link/activity) - Yellow LED lights On when the Ethernet cables are 

connected and terminated correctly, and blinks when receiving Ethernet 
data packets.

Changing the IP Address on the DAS-MNET

If the DAS-MNET fails to establish an IP Address via DHCP (the default 
setting), it automatically assigns the following arbitrary IP Address and Subnet:

IP Address = 192.168.1.200
Subnet = 255.255.255.0

In this case, you will have to change the IP Address via the Mi-Control software 
application (v1.0.3 or higher), available for download from www.amx.com. 
Download and install the software first, and refer to the online documentation 
for further details.

Note

: The Mi-Control software application must reside on a PC that is on the 

same subnet as the target Mi-Series Controller in order to communicate with 
the Controller.

1.

Launch the Mi-Control software. The initial view is the Main screen shown 
in FIG. 7. This screen displays various info specific to the Mi-Series 
Controller. 

2.

Click the 

Select

 button to access the 

Details

 screen (FIG. 8): 

3.

Click the 

Advanced

 button to access the 

Control Configuration

 screen 

(FIG. 9): 

4.

Select the 

Use Static IP

 option to enable the 

IP Address

Subnet

 

Mask

 

and 

Gateway

 fields.

5.

Enter the IP Address information as desired and click 

OK

 to apply your 

changes.

FIG. 6  

Ethernet Port LEDs

SPD

 - Speed LED 

connection speed is 100 Mbps

and turns Off when 

lights (green) when the

L/A

 - Link/Activity LED

lights (yellow) when the
Ethernet cables are
connected and
terminated correctly.

speed is 10 Mbps.

FIG. 7  

Mi-Control software - Main screen

FIG. 8  

Mi-Control software - Details screen

FIG. 9  

Mi-Control software - Control Configuration screen

Click “Select” to access
the Details page

Click 

Advanced

 to access the Control Configuration screen

Controller

 must be selected in order to access the Ethernet Settings