HPX-PA-HVI High Voltage Isolator
32
HPX-1600 Retractable Connection Port
Step 1 - Install Low-Voltage Secondary Circuit Modules
Install all low-voltage, secondary-circuit modules into the HPX-1600 Hydraport Base Assembly from the
bottom of the unit according to the instructions supplied with the HPX-1600 and or low-voltage, secondary-
circuit modules. For more information refer to the HPX-1600 Operation Reference Guide.
Position the cables coming from the low-voltage, secondary-circuit modules along the sides of the aluminum
chassis. These cables will pass along the outside of the folded High Voltage Isolator and exit the unit through
the square openings in the bottom cover.
Step 2 - Fold the High Voltage Isolator
Use the score lines on the High Voltage Isolator to fold the paper into the shape shown in Figure 1. Interlock
the two tabs and slots at the top of the part with the square tab (back) folded inside the interlocking tabs
(sides).
Pre-crease the folds as required to achieve a sharp, square fold.
Step 3 - Insert the High Voltage Isolator
Insert the High Voltage Isolator into the HPX-1600 Base Assembly so that the low-voltage, secondary-circuit
cables exiting the chassis are trapped along the sides of the chassis. See Figures FIG. 30 and FIG. 31.
All low-voltage, secondary-circuit modules must be installed above the AC Mains
Power Outlets and Circuit Breakers in the HPX-1600.
FIG. 30
High Voltage Isolator Installed
FIG. 31
High Voltage Isolator Cross Section
Trim High-Voltage
Isolator here
Position top of High-Voltage
Isolator here
Isolator
AC Power wires here
Low-Voltage Cables here