background image

Quick Start Guide

Flush Mount Rough-In Box

 for Modero X 7” Panel

4

A

Overview

The Flush Mount Rough-In Box (

FG5968-83

) is an optional accessory for the Modero 

X Series 7” Wall Mount Touch Panel. It is designed to be flush mounted in new 
construction applications into solid walls (rock, concrete, adobe, cinder block) or 
drywall. 
The back of the Modero X Series 7” Flush Wall Mount Touch Panel is contained within 
a plastic outer housing or 

back box

, and the back box attaches to the Rough-In Box. 

The Rough-In Box kit includes a wall box, cover, and mounting screws.

Specifications

Wall Mount Install of the FG5968-83 Rough-In Box

1.

Remove the cover (

B

 in FIG. 1) off of the rough-in box (

A

) before installation. 

CAUTION:

 The cutout dimensions shown will allow the unit to pass through without 

any dragging or interference. The outer phantom lines show the perimeter of the 
mounting flange. If any part of the cutout extends up to or beyond that perimeter, the 
cut edge will be visible after installation, or the unit could fall through the opening.

Solid Wall/Old Construction

1.

Cut a hole in the wall using best practices according Fig D below.

2.

Insert the box into the cutout until the front tabs are seated flush (Fig D).

3.

Screw or anchor to the wall through some of the various holes in the sides and 
back of the box. Snap off the four tabs once box is secured and continue with 
step 5 below.

Drywall and Stud Mounting

1.

Break the four bent tabs around the front of the box off (Fig C).

2.

Mount the metal box with its leading edge flush with the stud.  

3.

Remove the appropriate wiring knockouts from the rough-in box to 

accommodate the cables being threaded through to the wall mount touch panel.

4.

Thread the incoming Ethernet and USB wiring through the knockouts. Using the 
left wiring knockouts for USB connector cables and the right wiring knockouts for 
the LAN/PoE In cable is very highly recommended with this installation. Leave 
enough slack in the wiring to accommodate installation of the flush mount kit.

5.

After drywall is installed (with cover removed), use a rotary cutting tool or drywall 
saw to cut to the inside dimensions of the rough-in box. If using the included 
front cover, small notches may be needed to clear the four raised tabs on the 
cover. Do not shave off more drywall than necessary for clearance to insure that 
the flush mount kit will cover the entire opening after installation.

NOTE:

 The front cover (B in FIG. 1) should be installed after the appropriate wiring is 

pulled to the Rough-In Box. The cover should then be removed prior to the installation 
of the touch panel back box and discarded.

FIG. 1  

FG5968-83 Flush Mount Rough-In Box 

8.19”

 (20.8 cm)

A

B

7.68” (19.5 cm)

5.31”

(13.48 cm)

Rough-In Box

Rough-In Box With Cover

Cover

FG5968-83) Specifications

Dimensions 

• Rough-In Box: 8.19" x 7.68" x 3.47" (20.8 cm x 19.5 cm x 8.8 cm)

Weight

• Without cover: 1.80 lbs (0.82 kg)

Certifications

• UL Listed

Included 

Accessories:

• Cover Plate to cover Rough-In Box  (

62-5968-85

)

• Rough-In Box Cover Mounting Screws (2)  (

80-5967-04

)

5.347

(13.581 cm)

7.805”

(19.825 cm)

C

D

Install Flush With
Front Of Stud

NEW CONSTRUCTION

Remove Four 
Front Tabs

Screws In Stud

   (Pre-1/2” Wallboard)

Insert Box Until Four
Front Tabs are Flush.

Break Side Stud Tabs Off
So Box Clears Cutout.

Attach to Back or Side
of Solid Wall with Proper
Anchors. (Not Included)

SOLID WALL MOUNTING

Snap Off Once Box
is Secured.

Rough-in Box Must Be Secured
On Both Left and Right Sides

SOLID WALL CUTOUT

Outline Shows Perimeter of Flush
 Mount Flange After Installation

Stud Spacing
7.68 (19.5 cm)

(Not Included)