Initial Configuration
23
NetLinx Integrated Controllers (Firmware v4)- WebConsole & Programming Guide
8.
Click
OK
to save your newly entered information and close the
Communication Settings
dialog and return to the
Master
Communication Settings
dialog. Note the selected IP address is indicated in the
Configuration
field (FIG. 23):
9.
Click
OK
to begin the communication process to your Master (and close the dialog).
If you are currently connected to a Master, a pop-up asks whether you would want to stop communication to the current
Master and apply the new settings.
Click
Yes
to interrupt the current communication from the Master and apply the new settings.
10. Click
Reboot
(from the
Tools > Reboot the Master Controller dialog
) and wait for the Master to reboot.
NOTE:
On the front panel of the NetLinx Master, the STATUS and OUTPUT LEDs should begin to alternately blink during the
incorporation. Wait until the STATUS LED is the only LED to blink.
11. Click the
OnLine Tree
tab in the Workspace window to view the devices on the System.
The default System value is one (1)
.
12. Right-click the associated System number and select
Refresh System
. This establishes a new connection to the specified
System and populates the list with devices on that system.
The communication method is then highlighted in green on the
bottom of the NetLinx Studio window.
NOTE:
If the connection fails to establish, a Connection Failed dialog appears. Try selecting a different IP Address if
communication fails. Press the Retry button to reconnect using the same communication parameters. Press the Change button
to alter your communication parameters and repeat the steps above.
FIG. 23
NetLinx Studio - Communication Settings dialog (Configuration field indicating the selected IP Address)