background image

Quick Start Guide

AutoPatch

 DG DVI MTP

 

 Fiber Modules

Overview

DG (Digital Generation) DVI MTP

®

 Fiber Transmitter (TX) and Receiver (RX) Modules 

work together (FIG. 2) or in conjunction with MTP Fiber boards on an AMX AutoPatch 
Distribution Matrix. This guide contains complete information for standalone use. 
For use with a distribution matrix, see the distribution matrix’s instruction manual on 
the AMX AutoPatch Software & Documentation CD or visit www.amx.com
A table containing EDID resolutions is included on the reverse.

Product Specifications

Mounting Options

Desktop – attach the rubber feet (included) on the bottom of the module.

Rack Trays & Mounting Brackets – contact your AMX representative for details.

Installation

Typical System Setup

The TX receives DVI-D signals from 3 source devices and sends them over one fiber 
cable. The RX accepts the signals from the fiber cable, converts the signals back to 
DVI-D, and sends each signal to its corresponding destination device. 

Attaching Connectors

Note:  The DVI connector numbers on the TX and RX correspond to the Video Signal 
indicators on the front of the TX.

To attach connectors:

1.

Check EDID switch on front of TX to be sure that it remains set to the right (WP).

2.

For each source device, insert the DVI connector into the DVI jack on the rear of 
the TX (FIG. 3). For DVI-I pinout, see FIG. 5.

3.

For each destination device, insert the DVI connector into the DVI jack on the 
rear of the RX.

Caution:  Do not severely bend or kink the fiber cable. These 
actions can cause irreversible damage to the cable.

4.

Insert the MTP/MPO plug on one end of the fiber cable into the Fiber (MTP/MPO) 
jack on the front of the TX (FIG. 4).

5.

Insert the other end of the fiber cable into the Fiber jack on the front of the RX.

6.

For each destination device, insert its DVI plug into a DVI jack on rear of the RX.

7.

Insert the power plugs into the power jacks on the TX and RX (FIG. 4).

8.

Plug the power transformers into the power sources.

DVI-I TX & RX Module Connector Pinouts

* The +5 V on pin 14 on the TX Module will supply a maximum of 55 mA.

TX LED Indicators

Video Signal Indicators

Numbering corresponds to the numbering for DVI connectors on the rear of the TX.

Green – DVI signal path has a valid signal

Red – DVI signal path has lost its signal

Fault Indicator (Optical)

OFF – Optical converter is functioning normally

Red – Optical converter has a fault condition

Troubleshooting

If an indicator on the TX is red, check its corresponding connector and the 
corresponding connector on the source device and then cycle power on the TX.

MTP

®

 is a registered trademark of US Conec, Ltd.

FIG. 1  

      Transmitter (TX) FG1010-60                                       Receiver (RX) FG1010-63

Product Specifications

Approvals

CE

Power Consumption (max.) 

+12 V - +24 V DC, 14 W 

Power Connector

2.1 mm DC power jack

Humidity

0 to 90% non-condensing

Operational Temperature

32° - 110° F (0° - 43° C)

Dimensions

5.22 in. (13.26 cm) depth
5.82 in. (14.78 cm) width
1.42 in. (3.61 cm) height without feet

Weight

Approximately 1.5 lbs (0.68 kg) 

Compatible AMX AutoPatch   
Fiber Equipment

DVI 

MTP Fiber Modules

RGBHV - MTP Fiber Modules
Other AMX AutoPatch MTP Fiber products

Resolution Support

Up to 1920x1200 @ 60 Hz refresh rate w/ reduced blanking
Up to 1600x1200 @ 60 Hz refresh rate

DDC/EDID Support

EDID provided by DVI TX Module 

(EDID resolution list on back)

Pixel Bandwidth (bit rate)

1.65 Gbps

Specification Compliant

DVI 1.0, DVI-D (single link DVI)

HDCP Support

No

Input Cable Equalization

Up to 50 ft. (15.24 m)

Fiber Cable Types

12 Fiber Multimode MTP, 50/125 

µ

or 62.5/125

 

µ

Fiber Cable Length

Up to 3000 ft. (914.4 m) cable requires low loss, controlled 
skew fiber cable, such as, Alcoa 50/125 

µ

m Laser-Link 550

Fiber Cable Termination

Female MTP

Fiber Connector on Module

Male MTP (guide pins define it as a male)

DVI Connectors

DVI-I (DVI-D is supported signal type)

FIG. 2  

Typical system setup

Front

Rear

DVD

Fiber up to 3000 ft. (914 m)

FG1010-60

FG1010-63

TX

 

RX 

Source devices

Destination devices

FIG. 3  

Attach DVI connectors

FIG. 4  

Attach fiber cable & power cable

FIG. 5  

TX & RX DVI-I input & output pinouts

DVI connectors

Power jack

Power indicator

Video Signal indicators

Fault indicator

MTP connector

EDID switch remains

    

so source & destination

       can share information.

   set to WP (Write-Protect),

Отзывы: