consumption limits, you can connect a local 12 VDC power supply to the 
AXlink connector.

Preparing Captive Wires

You will need a wire stripper and a flat-blade screwdriver to prepare the 
captive wires:

1.

Strip 0.25 inch (6.35 mm) of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector 
according to the wiring diagrams in this section. 

3.

Turn the flat-head screws clockwise to secure the wire in the 
connector.

Note: Do not over-torque the screw. Doing so can bend the seating 
pin.

Wiring Guidelines

The AXR-IRSM+ requires 12 VDC power to operate properly. The power 
is supplied by the AMX system's AXlink cable. The maximum wiring 
distance between the Central Controller and the receiver is determined by 
power consumption, supplied voltage, and the wire gauge used for the 
cable. The following table lists wire sizes and the maximum lengths 
allowable between the receiver and the Central Controller. The maximum 
wiring lengths are based on a minimum of 13.5 volts available at the 
Central Controller's power supply.        

If you install the unit farther from the Central Controller than 
recommended in this table, connect an external 12 VDC power supply, as 
shown in FIG. 7.

Connection and Wiring

Wiring the AXR-IRSM+ AXlink

Install the AXlink data/power bus wiring as shown in FIG. 6.

Using the AXlink connector with an external 12 VDC power supply

Use a 12 VDC power supply when the distance between the Central 
Controller and the sensors or receivers exceeds the limits described in the 
Wiring Specifications table above. Make sure to connect only the GND 
wire on the AXlink connector when using a 12 VDC power supply (FIG. 7).

Note: Do not connect the PWR wire to the AXlink connector's PWR 
(+) terminal on the Central Controller's side.

Checking IR Data Status

Locate the red IR Data LED on the front of the unit (FIG. 1). Point the 
system's AMX transmitter towards the sensor and press a button. The IR 
Data LED lights when the unit receives data. 

If the IR Data LED does not light:

Verify that the transmit LED on the transmitter lights when you press 

a button.

Check the wiring to the unit.

Verify that the transmitter frequency is properly configured.

Checking AXlink Status

The AXlink LED lights to indicate AXlink power/data status as follows:

If the LED is On and not flashing, disconnect the AXlink connector and 
recheck all AXlink connections. Then, reconnect the AXlink connector to 
the panel and verify the LED is flashing once per second.

Mounting the AXD-IR+

Installation method A: 

Use when installing the swivel-mount unit without 

using the provided mounting bracket. The cable exit is on the back 
mounting panel (FIG. 8).

Installation method B:

 Use when installing the swivel-mount unit using 

the provided mounting bracket (FIG. 9).

On drywall, use the included wall anchors. Use a 3/16” drill bit.

On wood, install using the included #6 mounting screws.

Wiring Specifications @ 35 mA

Maximum Wiring Length

Wire Size

Distance

18 AWG

3000 feet (914.40 m)

20 AWG

2121.64 feet (646.68 m)

22 AWG

1,322.75 feet (403.17 m)

24 AWG

833.80 feet (254.14 m)

FIG. 6  

AXlink wiring

FIG. 7  

AXlink wiring with an external 12 VDC power supply

1
2
3
4

1
2
3
4

AXlink connector

on the 

Central 
Controller

GND

AXM

AXP

PWR

GND
AXM
AXP
PWR

AXR-IRSM+

1
2
3
4

1
2
3
4

AXlink connector

on the 

Central 
Controller

GND

AXM

AXP

PWR

GND
AXM
AXP
PWR

12 VDC
Power 
Supply

PWR
GND

AXR-IRSM+

• 1 blink per second

Indicates power is active and AXlink communication is working.

• 2 blinks per second

Indicates the devices specified in the Master program do not match the 
devices found.

• 3 blinks per second

Indicates AXlink communication error.

• Full On

Indicates the following conditions:
• There is no AXlink control or activity, but power is On. 
• The Axcess program is not loaded.

FIG. 8  

Installation Method A

FIG. 9  

Installation Method B