background image

Product Information

2

AXB-REL8 Axcess Relay Controller

Specifications (Cont.)

Dimensions (HWD)

1.51" x 5.55" x 5.45" (3.84 cm x 14.10 cm x 13.84 cm)

Enclosure

Non-glare, high-impact black matte plastic

Power Consumption

Baseline draw

With all 8 relays On

• 90 mA @ 12 VDC (min)

• 170 mA @ 12 VDC (max)

Front Panel Components

AXlink Status indicator

AXlink LED (green and blinks to indicate AXlink communication activity and

power:

• Full-Off indicates no power is being received or the controller is not 

functioning properly.

• One blink per second indicates power is active and AXlink communication is 

functioning.

• Full-On indicates there is no AXlink control or activity, but power is On.

Device DIP switch

An eight-position DIP switch is used to set the device number for the 
AXB-REL8.

Relay LEDs 1-8 (Red)

Illuminate when associated relay is closed. Relay LED's should match panel 
control function.

Rear Panel Components

AXlink connector

Four-pin captive wire receives power and information via the AXlink bus and 
AXlink system controller.

Relay contacts

Eight (normally -open) isolated two-pin relay contacts 1 A @ 28 VAC or VDC:

• Relays 1-4   can share a common 

if use

 jumper"A" pins with a tab strip

• Relays 5-8   use discrete commons (wire commons individually)

Содержание AXB-REL8

Страница 1: ...instruction manual AXlink Bus Controllers AXB REL8 Axcess Relay Controller ...

Страница 2: ... liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised ...

Страница 3: ...tting the DEVICE Dip Switch 3 Wiring Requirements 3 Preparing captive wires 4 Wiring guidelines 4 Connecting the Wiring 4 AXlink data and power connections 5 Wiring AXlink with optional 12 VDC power supply 5 Checking the installation 5 Relay connections 5 Testing the installation 6 Rack Mounting the AXB REL8 optional 6 System Worksheet and Installation Guide 7 ...

Страница 4: ...ii AXB REL8 Axcess Relay Controller Table of Contents ...

Страница 5: ...cess Relay Controller FIG 1 AXB REL8 front and rear views Specifications Dimensions HWD 1 51 x 5 55 x 5 45 3 84 cm x 14 10 cm x 13 84 cm Enclosure Non glare high impact black matte plastic Power Consumption Baseline draw With all 8 relays On 90 mA 12 VDC min 170 mA 12 VDC max Weight 17 50 oz 496 11 g Included Accessories Metal tab strips included for external adjacent relay communing Optional Acce...

Страница 6: ... per second indicates power is active and AXlink communication is functioning Full On indicates there is no AXlink control or activity but power is On Device DIP switch An eight position DIP switch is used to set the device number for the AXB REL8 Relay LEDs 1 8 Red Illuminate when associated relay is closed Relay LED s should match panel control function Rear Panel Components AXlink connector Fou...

Страница 7: ...The following table shows the switch numbers and their corresponding values As an example the following DIP switch FIG 2 defines the AXB REL8 as device number 97 1 32 64 97 Set the AXB REL8 device number before connecting AXlink wiring Do not install relay wiring at this time Wiring Requirements The AXB REL8 uses a four pin AXlink Central Controller connector for power and data If the distance bet...

Страница 8: ...on the maximum power consumption rating of 170 mA all eight relays ON The maximum wiring lengths for using AXlink power are based on a minimum of 13 5 volts available at the Central Controller s power supply If the AXB REL8 is installed farther away from the control system than recommended in the above table connect a 12 VDC power supply to the AXlink connector on the AXB REL8 rear panel see Wirin...

Страница 9: ...l 12 VDC power supply wire to the control system s power supply side of the AXlink connector FIG 4 Checking the installation After set up is complete 1 Check continuity of relay wiring 2 Check cable numbers and wiring interfaces and sources against supplied documentation 3 Install tab strips to jumper between shared commons and clip off excess tabs 4 Insert relay wiring terminals into AXB REL8 Rel...

Страница 10: ...nt the AXB REL8 into the optional AC RK Accessory Rack Kit 1 Remove any connected relay and AXlink connectors from the rear panel 2 Remove the two screws on the front panel of the AXB REL8 3 Remove the front panel and the space bracket behind the panel 4 Place the unit in the appropriate opening in the AC RK 5 Place the front panel of the AXB REL8 on the front of the rack over the unit 6 Fasten th...

Страница 11: ...m Worksheet and Installation Guide AXB REL8 Dealer ID Dealer PO Job SO Description Serial AXlink AXM GND PWR AXP B B 7 8 A B A 5 6 A B B B 4 A B A 2 3 A B A 1 A Wiring 4 3 2 1 B B A A B A B A 6 5 B A B A Function Color Pin 8 7 B A B A AMX Cable Infc Source Device ...

Страница 12: ...ive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 032 004 1021 6 02 2002 AMX Corporation All rights reserved AMX the AMX logo the building icon the home icon and the light bulb icon are all trademarks of AMX Corporation AMX reserves the right to alter specifications without notice at any time In Canada doing business as Panja Inc ...

Отзывы: