background image

Содержание Ambreeze

Страница 1: ...USER MANUAL WARRANTY INFORMATION ...

Страница 2: ......

Страница 3: ...PURIFICATION SYSTEM STRUCTURE BEFORE FIRST USE PLACING THE FILTERS UV LAMP REPLACEMENT OPERATION GUIDANCE CONTROL PANEL INDICATORS CONNECTING TO WI FI MAINTENANCE CLEANING FILTER REPLACEMENT WARRANTY WARRANTY REGISTRATION NINETY 90 DAY SATISFACTION GUARANTEE ...

Страница 4: ...duce the air flow Do not expose the unit to rain and do not use in a wet area Do not place the unit near a bathtub or a kitchen sink This appliance is not intended for use by people including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are being supervised or instructed by a person responsible for their safety Do not operate with a ...

Страница 5: ...circuit may occur as a result Do not use the Air Purification System if the power cord or plug is damaged or the connection to the wall outlet is loose Do not use this Air Purification System near gas appliances or fireplaces Do not place the appliance directly below an air conditioner to prevent condensation from dripping into the appliance Do not use this appliance when you have used indoor smok...

Страница 6: ...airs to help extend the life of the HEPA and activated carbon filters 2 True HEPA filter with anti bacterial coating The high perfor mance composite HEPA filter is over 99 97 efficient in trapping all allergens and airborne contaminant down to 0 3 micron in size such as lung damaging dust mould spores plant spores pet dander pollen etc 3 Activated carbon filter The activated carbon filter filters ...

Страница 7: ...1 2 3 4 5 6 7 9 8 5 STRUCTURE 1 Front cover 2 Pre filter 3 HEPA filter 4 Activated carbon filter 5 Control panel 6 Handle 7 Air outlet 8 UV C lamp 9 Dust sensor and filter reset button ...

Страница 8: ...the appliance Step 3 Remove HEPA filter from the appliance Step 4 Remove activated carbon filter from the appliance Step 5 Remove all packaging material from the filters Step 6 Place activated carbon filter back into the appliance making sure the side with strip faces towards you Step 7 Place HEPA filter back into the appliance making sure the side with strip faces towards you Step 8 Place pre fil...

Страница 9: ...very 10 000 hours 1 Open the UV lamp cover by a screwdriver 2 The UV bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting the bulb 1 4 turn Remove from unit 3 Install the new UV lamp and re attach the cover Note DO NOT look into the UV lamp when it is ON ...

Страница 10: ... indicate the operation time you set ranging from 1 12 hours Auto button pressing this button will adjust the fan speed according to the current air quality in the room The Air Purification System continually scans the air quality and adjusts function to best purify the air Sleep mode Wi Fi button press once to turn on sleep mode The indicator will blink for 10 seconds then switch of all lights on...

Страница 11: ...eeds about 2 minutes to detect the surrounding air quality After 2 minutes of operation the air quality indicator will indicate current air quality Heavily Polluted Lightly Polluted Moderate Good PM2 5 150 RED PM2 5 100 149 9 ORANGE PM2 5 50 99 9 YELLOW PM2 5 0 49 9 BLUE The TuyaSmart application works as a remote control for the unit Download the free app to your smart device and use it when you ...

Страница 12: ... Fi connection for the initial set up of the Air Purification System 2 Log in or sign up to the app Allow notifications allow access to your location access to your home data 3 Turn on the Air Purification System and check the Wi Fi icon on the Air Purifica tion System s control panel The Wi Fi icon should be blinking rapidly as you prepare to pair your devices If the Wi Fi light is off or stable ...

Страница 13: ...t using a vacuum cleaner under low speed only for the HEPA filter or soft brush to clean off dust particles from the filter This will help to extend the life of both filters and provide optimum performance The HEPA and activated carbon filter s life and optimum performance is based on air quality and regular maintenance but on average last 6 months Make sure to unplug the Air Purification System f...

Страница 14: ...on swab 5 Reattach the sensor cover Note Do not use any corrosive or flammable products to clean the appliance which may cause permanent damage When not in use for an extended time please pack and store well to protect the appliance If using after an extended storage time please follow as below 1 Clean the pre filter and make sure it is dry 2 Use soft cloth brush to clean the HEPA and activated ca...

Страница 15: ...r use of non AMBREEZE Air Purification System parts or accessories RIGHTS OF THE PURCHASER If any Air Purification System that has not been subjected to abuse accident physical damage misuse alterations neglect or improper temperature proves to have been defective during the Warranty period Amway will at Amway s option and subject to timely notification of the claimed defect either repair or repla...

Страница 16: ...ed under Australian or New Zealand law Amway limits its liability for incidental or consequential damages This warranty does not affect the Purchaser s statutory rights under applicable Consumer Protection Legislation Unless otherwise required under Australian and New Zealand law no person is authorized to modify or expand the Warranty provided herein waive any of the conditions and limitations of...

Отзывы: