background image

Quick Reference Guide

XLR8/XLR8 Plus

Features

Therapy Mode

“C” = Continuous

“V” = Variable

Target Pressure

Battery Indicator

USB Entry

Used for engineering 

purposes only.

Actual Pressure

This number will naturally 

fluctuate above and below 

target pressure.

Suction Strength

Green Bars = seal is adequate

Red Bars =  

seal may be compromised

System Status

Green Check (

) =  

proper function

Red Exclamation (

!

) = problem

On/Off Button

Up/Down Arrow Buttons

Press in main screen to increase/decrease pressure setting. 
In Menu/Select screen, press to scroll through menu and 

implement functions.

Lock/Unlock Button

Power Jack Inlet 

Used to charge unit.

Keypad Lock/Unlock  

Status

Red = Locked

Green = Unlocked

Time and Date

Menu/Select Button

Press to silence or lock in 

user changes.

Exit/Cancel Button

Press to go back to previous, 

or main screen.

Treatment Time

Indicates time therapy 

has been in progress.

Service needed

6 month PM or 4000 hour 

check recommended.

XLR8/XLR8 Plus

Quick Reference Guide

Application Guide

XLR8/XLR8 Plus

Questions?   

Call 1.800.208.2025 or 516.217.0010  |  email [email protected]  |  www.genadyne.com

©2016 Genadyne Biotechnologies, Inc.   CLN-003   02/16

Step 1

Select appropriate size dressing kit for 

wound.  Kit contains foam, port pad,  

and 2 drapes.  (Small kit has  

1 drape only.)

Step 2

Clean the wound according to protocol.  

Protect wound edges with drape.

Step 3

Cut foam to fit accurately in wound  

bed.  Avoid overlapping onto intact  

skin.  Avoid cutting foam over wound.   

Avoid over-packing, as this will inhibit 

filtration of drainage.

Step 4

Cover foam with drape by separating  

bottom layers 1 and 2 to expose the  

adhesive drape.  Position and place  

drape over foam.  Remove stabilization 

layers 1 and 2, then top with layer 3.   

Remove white ruler tab.

Step 5

Cut a hole in drape the approximate size 

of a quarter.  Remove paper backing 1 from 

bottom of the Port Pad.  Position Port Pad 

opening over the hole that was created.  

Remove backing 2 from the top of Port Pad.  

Flip handler tabs over on each side and  

peel down to remove.

Step 6

Select canister size and attach to the 

back of the pump.  Connect the port  

pad to the canister by securing the  

purple luer lock. 

Step 7

Initiate therapy by pressing the  

universal on/off button

.  Adjust 

pressure as prescribed using the  

up/down arrows.

Step 8

A secure seal is identified when the  

foam draws down and the target  

pressure is reached.

...................................................................................................................................................................................................................................................................................................

Questions?

 Call 877.790.5994  |  JMeds.com 

©

JMeds 2020

XLR8/XLR8 Plus

Application Guide

Application Guide

XLR8/XLR8 Plus

Questions?   

Call 1.800.208.2025 or 516.217.0010  |  email [email protected]  |  www.genadyne.com

©2016 Genadyne Biotechnologies, Inc.   CLN-003   02/16

Step 1

Select appropriate size dressing kit for 

wound.  Kit contains foam, port pad,  

and 2 drapes.  (Small kit has  

1 drape only.)

Step 2

Clean the wound according to protocol.  

Protect wound edges with drape.

Step 3

Cut foam to fit accurately in wound  

bed.  Avoid overlapping onto intact  

skin.  Avoid cutting foam over wound.   

Avoid over-packing, as this will inhibit 

filtration of drainage.

Step 4

Cover foam with drape by separating  

bottom layers 1 and 2 to expose the  

adhesive drape.  Position and place  

drape over foam.  Remove stabilization 

layers 1 and 2, then top with layer 3.   

Remove white ruler tab.

Step 5

Cut a hole in drape the approximate size 

of a quarter.  Remove paper backing 1 from 

bottom of the Port Pad.  Position Port Pad 

opening over the hole that was created.  

Remove backing 2 from the top of Port Pad.  

Flip handler tabs over on each side and  

peel down to remove.

Step 6

Select canister size and attach to the 

back of the pump.  Connect the port  

pad to the canister by securing the  

purple luer lock. 

Step 7

Initiate therapy by pressing the  

universal on/off button

.  Adjust 

pressure as prescribed using the  

up/down arrows.

Step 8

A secure seal is identified when the  

foam draws down and the target  

pressure is reached.

...................................................................................................................................................................................................................................................................................................