background image

Specifications Information and Repair Parts Manual

5771-95, 5773-95, 5777-95, 577A-95, 

Submersible Pumps Contractor Series

                                       577B-95, 577D-95, 577E-95

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained
in the General Operating Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or
property damage! Retain instructions for future reference

.  

AMT reserves the right to discontinue any model or change specifications at any time without

incurring any obligation.
©2006 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company,  All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to insure proper operation. Unit must be clear of debris and sediment. Inspect for leaks
and loose bolts. Failure to do so voids warranty.

Submersible Pumps

Contractor Series

Refer to pump manual 1808-636-00 for General Operating and Safety Instructions.

Description

These versatile centrifugal Submersible Contractor pumps are
intended for use in residential, commercial, and industrial
settings. Examples include: Construction sites, waste water,
storm water, farming, mines, marine, basement, and other
general drainage applications involving sediment laden liquids
with small solids (see size chart below). Submersible design
means low noise and no priming issues. Each unit is
completely assembled and includes a self-cleaning semi-open
impeller featuring abrasion-resistant high chromium steel 

construction for durability. Pumps incorporate a mechanical
shaft seal with long lasting silicon carbide war faces and
feature a secondary shaft seal and oil chamber.
Pumps have a 3450 RPM electric motor fitted with an
unfinished power cord that requires field wiring (no controls are
supplied). Motors are rated continuous duty and single phase
units have automatic restart thermal overload protection.
Handle liquids from 40º to 104º F (4º to 40º C). For use with
non-flammable liquids compatible with pump component
materials.

Figure 1 - Dimensions

5771

2"

8.27

19.29

2.76

3/8

5773

2"

8.98

25.60

3.15

3/8

5777

3"

8.98

26.38

3.15

3/8

577A/577B

3"

9.13

23.82

3.94

3/8

577D/577E

4"

  10.71

28.35

4.92

3/8

(*) Standard NPT (female) pipe thread.

 
5771-250-00

         03/2010

Specifications Information and Repair Parts Manual

5771-95, 5773-95, 5777-95,

577A-95 577B-95, 577D-95 and 577E-95

Model

Dis*

           A

CP

W (Minimum

Max.

liquid height)

solid

Содержание Contractor Series

Страница 1: ...e centrifugal Submersible Contractor pumps are intended for use in residential commercial and industrial settings Examples include Construction sites waste water storm water farming mines marine basement and other general drainage applications involving sediment laden liquids with small solids see size chart below Submersible design means low noise and no priming issues Each unit is completely ass...

Страница 2: ...andle and outer shell Ref No 37 Shell can now be slid off towards top of pump 5 Clean dirt and rust from around wire cover Ref No 7 6 Remove two fasteners Ref No 4 which hold inner cord retainer Ref No 3 7 Remove four fasteners Ref No 10 which hold wire cover in place 8 Carefully pry cover from unit with screwdriver IMPORTANT Be careful to keep rust and other debris from falling into motor housing...

Страница 3: ... three fasteners Ref No 25 and pry out seal plate with screwdriver Slinger washer Ref No 24 will come free at this time 8 Use a press or gear puller to remove shaft and bearings from lower end bell Shaft seal head will now be free IMPORTANT Shaft seal head with spring has unique ends and two seal seats are different from one another Be sure to note size and color of each before disassembly so that...

Страница 4: ...o 35 See Ref No 35 1 20 Seal See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 1 21 Seal plate 22 Seal See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 1 23 Drain plug 1 24 Slinger wsher See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 See Ref No 35 1 25 Fastener 4 26 Impeller See Ref No 34 See Ref No 34 See Ref No 34 See Ref No 34 See Ref No 34 1 27...

Страница 5: ... 95 Submersible Pumps Contractor Series 577B 95 577D 95 577E 95 For Repair Parts contact dealer where pump was purchased Please provide the following information Model number Serial number if any Part description and number as shown in parts list Figure 3 Repair Parts Illustration ...

Отзывы: