Specifications Information and Repair Parts Manual
A200-90
A200-250-00
1
8/2013
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating
Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions
for future reference. AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
©2013 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so
voids warranty.
Mounting Frame
SPECIFICATIONS
Material: Steel Plate
Finish: Paint or powder coated finish, color: black
Weight: 44 lb. [20 kg]
Overall dimensions (max):
30” [762mm] long
14.2”[
360mm]
wide
5.1”
[130mm]
tall
GENERAL
Mounting frame is designed to support a pump end and driver while also
providing a convenient way to secure the entire assembly to a suitable
grounding base plane.
GROUNDING BASE PLANE
Mounting frame must be secured to a grounding base plane. Grounding
plane must be flat, level, and of sufficient strength and size to support the
entire frame/driver/pump assembly along with any loads the piping system
generates. Frame is designed to provide a convenient form of mounting the
driver/pump. It is not designed to handle excessive piping system loads or
provide total support in and of itself. Frame is designed to transfer the loads
to a flat grounding base plane that supports the entire frame. If frame is not
supported correctly, damage to frame and pump assembly may occur.
FRAME MOUNTING FASTENER LAYOUT
Refer to Figure 1
Frame mounting holes are sized to accommodate 3/8” [10 mm] diameter
fasteners. Ref. Drawing 1 is provided for fastener spacing and layout. Due
to dimensional tolerances and assembly variations, it is best to measure your
actual unit to determine the exact fastener spacing before installation.
VIBRATION
Mounting frame can be fastened directly to the grounding plane, but if unit
vibration is excessive during operation, pump damage may occur. Some form
of vibration dampening mount between pump/frame assembly and grounding
plane should be considered.
PUMP/DRIVER TO FRAME MOUNTING
Refer to Figure 2
If A200-90 mounting frame is purchased as an accessory to be mounted to a
pump in the field, follow the following instructions:
•
Measure vertical distance from pump end support foot or casing bottom to
motor mounting foot.
•
If distance is 0 to 1.3”, fasten motor to frame “driver mount” with bolts, nuts
and washers provided.
•
If distance is 1.3” to 2”, the driver support must first be repositioned.
Remove four M12 bolts holding driver mount to mounting rails. Move
driver mount up and install M12 bolts into lower set of holes in driver
mount. Realign frame cross members. Torque bolts to 35 ft-lb [47 N-m].
Fasten motor to driver mount with bolts, nuts and washers provided.
•
If distance is greater than 2.1”, motor must be spaced above driver mount
as needed. This will require longer bolts than supplied. Adding spacers will
void any warranty.
•
Loosen four M12 bolts securing pump support to mounting rails. Slide
pump support up until it supports the pump foot or casing bottom. If pump
foot has provisions for mounting bolts, holes must be drilled into the pump
support at the appropriate locations. Secure pump foot with appropriate
fasteners (not provided).
REPAIR/REPLACEMENT PARTS
Mounting frame is available as a complete unit only. Replace entire unit if
damage occurs.
DESCRIPTION
Mounting frame for 145/182/184/213/215JM motor driven pumps.