AMT 5150-96 Скачать руководство пользователя страница 1

Specifications Information and Repair Parts Manual  

     

5150-96

                                                      

5150-254-00

1

11/2012

Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate 

or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating 

Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions 

for future reference.  AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2012 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so 

voids warranty.

High Flow Drum Pump

Aluminum Model

UNPACKING

Inspect carefully for any damage that may have occurred during transit. Check 
for loose, missing or damaged parts. Transit damage claims should be made 
to the shipping company.

SPECIFICATIONS

Flow...................................................................................27 GPM at 120 RPM
Max. Liquid Temperature..............................................................160º F (71º C)
Mounting...................................................................................2” Bung Adapter
Inlet.........................................................................................................1” NPT
Outlet.......................................................................................................1” NPT
Spout...............................................................................................Plated Steel
Pump Housing............................................................................Cast Aluminum
Rotors.........................................................................................................Steel
Fasteners (non-wetted)...................................................................Plated Steel
Seals..........................................................................................Nitrile (Buna-N)
Suction Strainer...................................................................................#60 Mesh
Weight ..................................................................................................11.3 lbs.

GENERAL SAFETY INFORMATION

 

It is the responsibility of the user to operate the pump in conformance 
with OSHA rules for dispensing liquids. Pump containers should be 

grounded when using with flammable liquids to avoid static electricity. 

Pump should be washed out before usage since processing lubricants 

could contaminate the fluid.

1. 

When  using  a  hand  pump  (especially  when  pumping  flammable, 

combustible, or hazardous liquids) follow all electrical and safety codes, 
as well as the United States Occupational Safety and Health Act (OSHA), 
most recent National FIre Protection Association, Inc. † (NFPA) Code 
30 (Flammable and Combustible Code), NFPA 56A (Standard for use of 
Inhalation Anesthetics), NFPA 77 (Static Electricity), NFPA 78 (Lighting 
Protection Code), NFPA 80 (Standard Method of Fire Test of Building 

Construction), NFPA 704 (Identification of the Fire Hazards of Material(s), 

other NFPA codes, local codes and ordinances, as needed in a particular 
application. 

(†)Any of the NFPA Codes can be obtained from National Fire Protection 
Association, Inc., Batterymarch Park, Quincy, MA 02269, telephone 1-800-
344-3555. Write or call for listing and prices.

2.  Know the pump application, limitations and potential hazards. The 

WARNING statements indicate potentially hazardous conditions for 
the operator or equipment. TAKE NECESSARY STEPS TO PROTECT 
PERSONNEL AND EQUIPMENT. Pump should only be used with 
liquids compatible with pump component materials. Consult PUMP 
CHEMICAL COMPATIBILITY CHART and PUMP SPECIFICATIONS. 
Also, the chemical supplier should be consulted regarding any questions 
of chemical compatibility, proper and safe use and handling of chemical 
.Misapplication of pump or use of non-compatible liquids will void warranty.

 

In order to properly use this product familiarize yourself with this pump 
and also with the liquid (chemical, etc.) that is going to be pumped 
through the unit. Although this pump is suitable for many liquids, it is not 
suitable for all liquids! 

3. 

Pumping  hazardous,  flammable  or  combustible  liquids  should  only  be 

done in buildings, rooms or areas suited for this purpose (See NFPA 30, 
NFPA 78, NFPA 80, NFPA 251, NFPA 704, other suitable NFPA codes, 
OSHA, insurance companies, local codes and ordinances).

 

When filling cans, drums, etc. with combustible or flammable liquids, both 

container pumping from and container pumping to, should be bonded 
and grounded to dissipate possible accumulations of static electricity 
and minimize sparks caused by static electricity (refer to NFPA 77 for 

specifics and further details). 
Removal of outer garments in work areas where there may be flammable 
or explosive liquids, which are ignitable with low electrical energy can be 

fatal and/or cause property damage (refer to NFPA 56A, and NFPA 77 for 
further details).

4.  The WARNING and instructions for gasoline that follow pertain not only to 

gasoline, but to any flammable, combustible or hazardous fluid.

 

Gasoline  is  a  highly  flammable  fuel.  The  improper  use,  handling  or 
storage  of  gasoline  can  be  dangerous.  Prevent  accidents  by  following 

these safety rules: 

• 

Use gasoline only as fuel, never as a cleaning fluid. 

• 

Use only an approved container to hold or store gasoline. Never 

store gasoline in familiar containers such as milk or soda pop 
bottles. 

DESCRIPTION

This High Flow Hand-Crank Drum Pump is self-priming. It is used for dispersing and transferring lubricating oil, antifreeze (ethylene-glycol), fuel oil, gasoline and 
other noncorrosive, non-abrasive liquids compatible with pump component materials*.

(*) Always refer to a chemical resistance chart to confirm compatibility. Not rated for food products.

Содержание 5150-96

Страница 1: ...lar application Any of the NFPA Codes can be obtained from National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 telephone 1 800 344 3555 Write or call for listing and prices 2 Know the pump application limitations and potential hazards The WARNING statements indicate potentially hazardous conditions for the operator or equipment TAKE NECESSARY STEPS TO PROTECT PERSONNEL AND E...

Страница 2: ...PERSONAL SAFETY 1 Wear safety glasses at all times when working with pump 2 Wear a face shield proper apparel and suitable respiratory equipment when pumping hazardous chemicals 3 Keep work area clean uncluttered and properly lighted Replace all unused tools and equipment 4 Keep visitors at a safe distance from the work area 5 Make workshop child proof with padlocks master switches and by removing...

Страница 3: ...on and re tighten cover bolts 10 Damaged worn pump parts 10 Remove pump cover and inspect for broken pieces Components should have smooth finish no large grooves or voids Replace damaged parts Piston type pumps may include a poppet valve which is designed to prevent back flow If excessive leakage past valve is found replace valve some leakage is normal Handle difficult or impossible to move 1 Pump...

Страница 4: ...ual 5150 96 5150 254 00 4 11 2012 For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Figure 2 Repair Parts Illustrations ...

Страница 5: ...0 12 Gasket Kit 5150 302 90 1 13 Filter Body 5150 002 90 1 includes Ref Nos 13 14 16 and 17 14 Bottom Plate Incl w Ref No 13 1 15 O Ring Buna N 1 16 Suction Strainer Incl w Ref No 13 1 17 Retainer Ring Incl w Ref No 13 1 18 Fastener 3 19 Fastener 3 20 Bung Adapter C209 170 90 1 includes Ref Nos 20 21 and 23 21 Butterfly Screw Incl w Ref No 20 1 22 Suction Tuber Assembly 4820 172 90 1 23 Butterfly ...

Страница 6: ...Specifications Information and Repair Parts Manual 5150 96 5150 254 00 6 11 2012 NOTES ...

Страница 7: ......

Страница 8: ...www amtpump com ...

Отзывы: