AMT 3880-97 Скачать руководство пользователя страница 1

 

3880-252-00 

09/2011 

 

Specifications Information and Repair Parts Manual

 

 

 

                                                                   

3880-97 thru 3884-97

 

 

 

x

 

Please  read  and  save  this  Repair  Parts  Manual.  Read  this  manual  and  the  General  Operating  Instructions  carefully  before  attempting  to  assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are  contained 
in  the  General  Operating  Instructions.  Failure  to  comply  with  the  safety  instructions  accompanying  this  product  could  result  in  personal  injury  and/or 
property damage! Retain instructions for future reference

.  

AMT reserves the right to discontinue any model or change specifications at any time without 

incurring any obligation.

 

©2011 American Machine & Tool Co., Inc. of PA, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.

 

 

Periodic maintenance and inspection is required on all pumps to insure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure 
to do so voids warranty. 

 

Swimming Pool/Hot Tub Pumps 

Refer to pump manual 1808-634-00 for General Operating and Safety Instructions. 

  

DESCRIPTION 

These bronze centrifugal pumps are designed for high volume liquid handling in spas or other applications where moderate pressures and high volumes 

are  required. 

                                                                                                      to a wide variety of swimming pool 

filters.  All  units  are  manual  models.  No  controls  are  supplied.  For  use  with  nonflammable,  non-abrasive  liquids  compatible  with  pump  component 

materials.  

 

 

READ AND FOLLOW ALL INSTRUCTIONS 

 

To reduce the risk if injury, do not permit children to use product unless they are closely supervised at all times. 

 

 

This  pump  is  for  use  with  permanently  installed  pools  and  may  also  be  used  with  hot  tubs  and  spas  if  so  marked.  Do  not  use  with storable pools.  A 

permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily  disassembled for storage. A storable pool is 

constructed so that it may readily disassembled for storage and reassembled to its original integrity. For hot tub and spa pumps 

– do not install within an 

outer enclosure or beneath the skirt of a hot tub or spa unless so marked.  

 

Important Safety Instructions 

Save these instructions 

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 

 

A copper bonding conductor of no smaller than 8 AWG must be connected from the ground screw on the motor to ALL metal parts of the pool, spa or hot tub 

structure, and to all electrical equipment, metal conduit, and metal piping within 5 feet of the inside wall of a swimming pool, spa, or hot tub, when the motor is 

installed within 5 feet of the inside walls of the swimming pool, spa, or hot tub. For specific safety precautions for installation and electrical connection information 

and  to  reduce  the  potential  for  fire,  electric  shock,  or  injury,  read  and  follow  all  information  and  instructions  contained  in  the  form  1808-634-00,  Electric  Motor 

Driven Pumps Operating Instructions. 

NOTE:

 If the pump is located above the liquid level, a positive sealing foot valve must be installed at the end of the suction line or in the piping just before the 

pump. If the unit is used with a strainer basket, the foot valve or check value will be required only when the suction lift or distance the pump is from the water level 

is greater than 10 feet. If the strainer basket is not used, it is recommended that you use another suitable means of straining foreign material out of the suction line. 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 

MAINTENANCE 

 

 

Make certain that unit is disconnected from power source before attempting 
to service or remove any components!  

  

MECHANICAL SEAL REPLACEMENT 

Refer to Figures 1 and 2 
 

IMPORTANT:

 Always replace seal seat (Ref. No. 9) and seal head (Ref. No. 10) 

to insure proper mating of mechanical seal components. 
 
1. 

Unthread fasteners (Ref. No. 5) and remove casing (Ref. No. 13) and 
casing seal (Ref. No. 8) 

2. 

Unscrew  impeller  (Ref.  No.  12)  from  motor  shaft.  Remove  shims 
(Ref. No. 11) and retain for reassembly.  

NOTE:

 

S                           7/ 6”                                      

shaft (remove bearing cap for access) to prevent shaft from turning. Other motor 
shafts have a screwdriver slot instead of flats. 

 

3. 

Slide old seal head from motor shaft. 

4. 

Unthread fasteners (Ref. No. 6) and remove assembled adapter (Ref. 
No. 4) and casing cover (Ref. No. 7) from motor mounting face. 

5. 

Pry seal seat from rear of casing cover with a screwdriver. 

6. 

Clean casing cover seal seat recess before inserting new seal parts. 

7. 

Wet rubber portion of new seal seat with light coating of soapy water. 
Press  seal  seat  squarely  into  adapter  recess.  Avoid  scratching 
polished surface. 

NOTE:

  Handle  all  seal  parts  with  extreme  care  and  attention  to  keeping

 

them 

clean. Do not touch polished faces with your hands. Do not put lubricants of any 
kind on seal faces; this can cause seal to leak.  
8. 

Inspect polished face  of seal seat and polished face  of seal head to 
insure they are clean and not marred. 

9. 

Using  a  clean  cloth,  wipe  shaft  and  make  certain  that  it  is  perfectly 
clean. 

10. 

Slide  assembled  adapter  and  casing  onto  motor  mounting  face. 
Attached with fasteners. 

11. 

Wet  inside  rubber  portion  of  new  seal  head  with  a  light  coating  of 
soapy water. Slide head onto motor shaft. 

IMPORTANT:

  Reinstall  any  shims  or  spacers  which  may  have  been  removed 

onto motor shaft before installing impeller.  
12. 

Screw  impeller  back  in  place,  tightening  until  it  is  against  shaft 
shoulder. 

13. 

Replace casing seal and casing. Attach with fasteners.  

IMPORTANT:

 Always inspect casing seal when disassembled. Use a light oil or 

grease for ease of installation. 
Replace when cracked or worn.   

 

 

Figure 1- Mechanical Seal Replacement 

Отзывы: