AMT 3680 Series Скачать руководство пользователя страница 2

 

Specifications Information and Repair Parts Manual                                                                  3680, 3690 and 3700 Series 

 

3680-250-00 

9/2016 

 

Small Straight Centrifugal Pumps

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SHIM ADJUSTMENT 

 

1. 

When installing a replacement adapter (Ref. No.4), impeller 
(Ref. No. 8), or casing (Ref. No. 12) it may be necessary to 
vary  number  of  impeller  shims  (Ref.  No.  7)  that  will  be 
required. This is easily done by adding one shim more than 
was  removed  and  reassembling  pump  as  described  in 
“Mechanical Seal Replacement” section. 

NOTE: 

When  adding  or  removing  shims,  it  is  best  to  proceed  with  a 

0.010"  increment  each time. While  tightening  unit together  turn shaft; 
feel  for  shaft  seizing.  If  shaft  begins  to  seize  before  fasteners  are 
completely tight, disassemble pump and remove one shim and repeat 
assembly. 
2. 

Once  having  added  one  shim  more  than  original,  ensure 
that  casing  and  adapter  are  firmly  fitted  (check  fasteners 
Ref. No. 13). When pump shaft turns freely, add shims until 
it does strike, then remove a 0.010" shim. This should allow 
proper clearance. 

3. 

Proper running clearance for impeller should be as close as 
possible  to  volute  without  striking;  maximum  clearance  is 
1/32" (0.032"). 

4. 

Follow  above  procedure  until  proper  clearance  is  obtained. 
This will ensure maximum performance. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Отзывы: