Specifications Information and Repair Parts Manual
25FP Series
25FP-250-00
1
10/2017
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating
Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions
for future reference. AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
©2017 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so
voids warranty.
25FP Fire Pump Series
Refer to form 1808-633-00 for General Operating and Safety Instructions.
SPECIFICATIONS
Suction inlet.........................................................................2-1/2” NPT Female
Discharge outlet...................................................................2-1/2” NPT Female
Dimensions overall (Length x Width x Height)
25FP13AR & 25FP13HR..........................................................(32” x 32” x 25”)
25FP23AR................................................................................(41” x 32” x 25”)
Engine and fuel tank size
25FP13AR........................................................................B&S Vanguard 13HP
25FP13HR..................................................................................Honda GX390
25FP23AR........................................................................B&S Vanguard 23HP
25FP13ZR.........................................................................................Hatz 1B50
25FP10YR....................................................................................Yanmar L100
BASIC CONSTRUCTION
Pump is constructed of cast aluminum. Engine shaft is sealed with a self-
lubricating mechanical seal that consists of a silicon carbide stationary ring,
carbon rotating head, stainless steel spring and Viton® elastomer. Discharge
flange gasket and casing o-ring are Viton®.
UNPACKING
Refer to repair parts illustration and parts list to aid in identifying pump
components. Unpack and separate all pump components from shipping/
packaging materials, making sure all parts are accounted for. Retain all
manuals for future reference.
Package should contain:
• Pump/engine completely assembled and mounted in roll frame.
• Rubber feet with fasteners bag.
• Frame handle parts bag.
• Frame panel and parts bag.
• Engine owner’s manual
• Pump general safety manual,
• Specifications information and repair parts manual.
ASSEMBLY
Roll Frame Handle Assembly:
1.
Install pivot bearing (A6) in frame hole. Ends of bearing must be flush
with outside of frame rail.
2. Hold handle (A3) perpendicular to frame tube.
3. Slide handle end ears over frame tube until handle tube end contacts
frame.
4. Align handle ear hole with bearing in frame.
5. Install pivot pin (A5) and pin end cotter (A7).
6. Install lock pin (A4) in other handle ear hole. Secure with cotter (A7).
7. Handle can be locked in the up or down position with lock pin.
8. Repeat procedure for [3] three remaining handles.
Roll Frame Panel Assembly:
1. Slide panel mounting brackets (A10) over frame tube where panel will
be positioned.
2. Align slots in end of panel (A9) with holes in mounting brackets.
3. Fasten panel to brackets with bolts (A11) and nuts (A12) provided.
Rubber Feet Assembly:
1. Install bolt (A20) through rubber foot (A19) center hole.
2. Slide bolt through hole provided in lower tube of roll frame.
3. Fix in position with nut (A21).
4. Repeat for [3] three remaining feet.
Battery Tray Assembly:
1. Locate battery tray (A14) on frame rail.
2. Install mounting bolts (A15) with washers (A16), and nuts (A17).
3. Install “J” bolts in tray slots.
4.
Install hold down angle on “J” bolt threaded ends, fix with wing nuts.
Install Battery:
1. Maximum battery size is 5-1/4” wide X 7-3/4” long, 230 CCA (Cold
Cranking Amps) or greater U1/U1R Lawn and Garden battery.
2. Position battery in tray with (+) terminal towards engine end of frame
and (-) battery terminal towards pump end of frame.
3. Hold battery in position with hold down angle, “J” bolts, and wing nuts.
4. Connect engine starter red cable to battery (+) terminal and ground
black cable to (-) terminal with fasteners (not provided).
DESCRIPTION
This is a single-stage centrifugal pump designed for agriculture or fire fighting service. It is close coupled to an internal combustion air cooled engine and protected
by a roll frame equipped with four carry handles. The pump is compact and light-weight, designed for portability. Pump construction is rugged and allows for easy
maintenance.
Units are designed to handle clean water or water containing small (1/16” maximum spherical diameter) solids. Suction and discharge ports are 2-1/2” NPT
threaded. Discharge includes a built in bronze check valve to allow use of an exhaust or hand operated priming system.
Liquid temperature range is 40°F to 180° F (4°C to 82°C). Maximum casing pressure is 180 psi (1240 kPa). For use with nonflammable liquids that are chemically
compatible with pump component materials.
Содержание 25FP10YR
Страница 15: ......
Страница 16: ...www amtpump com...