Calibration & Configuration
This section discusses calibration, printing configuration and resetting the printer
to factory defaults.
Performing Calibration
After the media is loaded, please perform media calibration to calibrate the label
sensor in advance.
1. Turn off the printer
2. Press and hold the PAUSE button and turn on the power.
3.
When “CALIBRATION …” is displayed on the LCD , and both READY and
MEDIA indicators blink, release the PAUSE button.
NOTE: Printers with Ethernet will take 20 second for this process,
the PAUSE button must be pressed during that period.
4. The printer feeds 12-inches of blank labels.
5.
When “READY” is displayed, the READY and MEDIA indicators stop
blinking but remain illuminated.
Important! It’s recommended to perform media calibration after changing media.
Failure to do so could result in improper detection by the label sensor.