ESL15 Electronic Lock Operating Instructions 

The ESL15 uses a fixed length 6-digit combination. Your AMSEC ESL15 Electronic Safe Lock has a default factory 
combination of: 1-2-3-4-5-6. 

Opening Your ESL15 Lock for the First Time

 

1.

 

Press the “C” key. 

2.

 

Key in the factory preset combination. 

3.

 

Press the “#” key. 

If the combination was entered correctly, the lock will cycle open for three seconds. During this 3-second period, 
turn the handle of the safe to the unlocked position and pull the door open. 

Changing the ESL15 Master User Combination 

You may change your combination any time you’d like and as many times as you’d like. To insure security once 

your safe is installed, you must change the factory preset combination to a new 6-digit combination.  
 

CAUTION:

 Combination changes should always be done with the door OPEN to prevent accidental lockout. 

1.

 

Press the “C” key. 

2.

 

Press the “#” key. You should hear a short warbling tone and see the red LED flash. 

3.

 

Key in your old 6-digit combination. 

4.

 

Press the “#” key. You should hear a short good combination tone. 

5.

 

Key in your new 6-digit combination. 

6.

 

Press the “#” key. You should hear a short good combination tone. 

7.

 

Re-key in the new 6-digit combination again. 

8.

 

Press the “#” key. If the combination input matches the first pass, you should hear a long good combination 

tone indicating your new combination has been recorded. 

9.

 

Test your new combination several times prior to closing and locking the safe. 

Note:  

 

See the ESL15 Beep and LED Patterns table on Page 10. 

 

See 

Changing User Combinations

 section for instructions on changing combinations for Users other 

than the Master User. 

 
Low Battery Warning 

The ESL15 lock provides a warning when the battery is getting low.  

When the battery power drops to a near critical level, after a normal lock opening cycle is completed, a 

low battery warning warble tone will sound for 3 seconds and the keypad LED(s) will flash. The lock will 

not open soon.  
Change your Battery! 

 
A Few Things to Remember

 

 

With each keystroke, the red LED on the keypad will flash and the beeper will chirp. 

 

If 4 incorrect combinations are entered, the lock will go into Penalty Lockout for 15 minutes to prevent 
trial-and-error attempts at opening the lock. The red LED will flash once every 5 seconds during this period. 

Содержание ESL15

Страница 1: ...ion 4 Press the key You should hear a short good combination tone 5 Key in your new 6 digit combination 6 Press the key You should hear a short good combination tone 7 Re key in the new 6 digit combination again 8 Press the key If the combination input matches the first pass you should hear a long good combination tone indicating your new combination has been recorded 9 Test your new combination s...

Страница 2: ... pressed For example if you press C 1 2 3 4 5 7 4 5 2 7 6 the program recognizes only the C 1 2 3 4 5 6 input The last numeric key pressed continues to replace the one prior until the key is pressed to indicate completion This is a security feature that allows you to baffle any onlookers who may be trying to memorize your combination Replacing the Batteries Always use a fresh set of name brand Alk...

Страница 3: ...feature allows the Time Delay to be used under normal access situations but provides a means to bypass time delay when cash handling methods require that an Armored Car courier can take deposits without waiting for the delayed access o This feature must be Enabled F40 o It still requires that a valid resident User be present to open the safe o The Armored Car Code User 9 can be keyed in first foll...

Страница 4: ...ode is Enabled the Manager must be one of the two Users entering valid combinations Duress Alarm This feature allows a User to secretly signal that they are under Duress typically in the act of being forced to open the safe in a robbery situation o This feature must be Enabled F20 o This feature requires that one of the optional Expansion Modules ESL20EXP1 ESL20EXP2 or ESL20EXP3 is attached to pro...

Страница 5: ...er Code Feature Setting with Function Codes The ESL15 s advanced features are controlled only by the Master User and are set using Function Codes A function can be turned on and off or set using the Function Code with the Master User code as authorization for changing or setting the function A Function Code is a 2 digit code that is associated to a particular setting Each Function Code has a defau...

Страница 6: ...o set the Delay Period C 02 Master Code Delay Period 1 99 minutes o To set the Open Period C 03 Master Code Open Period 1 9 minutes Multiple User Settings Functions 10 11 12 13 o To Enable Multiple User Mode C 10 Master Code 1 o To Disable Multiple User Mode C 10 Master Code 0 o To Add or Enable a Subordinate User C 11 Master Code User Number 1 8 o To Disable a Subordinate User C 12 Master Code Us...

Страница 7: ... Combo Change C 60 Master Code 1 o To Disable Subordinate User Combo Change C 60 Master Code 0 Reset All Functions Function 99 o To Reset All Functions C 99 Master Code 1 Mixed Modes Any combination of modes can be active at the same time Here are some situations that are possible and how they interact together o Dual Combo and Time Delay Any one valid combo can start the Time Delay but after the ...

Страница 8: ... or 0 02 Time Delay Period 1 99 03 Open Period 1 9 10 Multiple User Mode 1 or 0 20 Duress Mode 1 or 0 30 Dual Combo Mode 1 or 0 31 Two Subord Combos Open 1 or 0 40 Armored Car TDL Bypass 1 or 0 41 Subord Auth of TDL Bypass 1 or 0 50 External Control Port 1 or 0 60 Subord User Combo Change 1 or 0 To track User assignments use this table User No Assigned To Date Assigned To Date Assigned To Date 0 1...

Страница 9: ... of the lock inside the door The ESL15 relies on a solenoid to actuate this bolt That solenoid can only overcome so much resistance and if that resistance is too great the bolt does not retract To resolve this problem you must find a handle position that does not push the locking system up against the lock s bolt To find that place it helps to know which way the handle turns when you open the door...

Страница 10: ...rt after Time Delay 6 Beeps The lock is in Penalty Lockout During this period the lock will not accept any input You must wait for the penalty lockout to expire The lock will Beep Flash once when this period ends Short Warble 3 high low tones for about 2 5 seconds Short Good Combination Tone indicates the input is accepted during a Combination Change Long Warble 13 high low tones for about 10 seco...

Отзывы: