Venus T5c Series

 

---Front Panel--- (see 

Figure 4

Figure 4 

D1:Temperature LED 
D2:Fan LED 
D3---D7: HDD Access and failure LED (Green LED 

is lighting when HDD link and blinking 
when HDD access; the LED will turn red 
when HDD failed. The green LED and red 
LED will alternate during rebuilding) 

D8:SYS LED: Lighting while system is ready   
D9:SYS Reset or Backup (option) 
D10:HDD Safety Lock 
D11:Power LED 
D12:Power Safety Lock (The safety lock prevent 

it bouncing out while HDD is working)

 

D13:120W Switching Power Supply 

---Rear View--- (see 

Figure 5

Figure 5 

E1:Cooling Fan #1 (8x8cm) 
E2:Fan Speed Control FAN RPM HIGH(3600rpm)&
      LOW(2800 rpm) Options(If you want the fan to 

    run at a high speed ,switch to the right; otherwise 

      , switch to the left 
E3: Cooling Fan #2 (8x8cm) 
E4: Reset/Change Mode (push button less than 2 

seconds for system reset / hold button over than 
2 seconds for apply new RAID mode) 

E5:RAID CONFIGURE SW 
E6:ESATA 
E7:Power SW 
E8:Power Input(AC 100V-240V) 

Содержание Venus T5c DS-2350C

Страница 1: ...www american media com Page 1 Venus T5c Series Venus T5c series SATA RAID User Manual Model DS 2350C Model DS 2250C For 3 5 SATA For 2 5 SATA ...

Страница 2: ... by DIP switch apply change mode switch LED indicators for System Ready HDD Error HDD Access Temperature fan 8x8cm Fan X 2 High Low speed selectable Reset switch or OTB switch for option Color BLACK Dim 215 L x156 W x211 H mm Patent products with advanced structure design Patent balance handle no skew in out problem and avoid the abrasion during connection Precisely connection on connector see Fig...

Страница 3: ... D10 HDD Safety Lock D11 Power LED D12 Power Safety Lock The safety lock prevent it bouncing out while HDD is working D13 120W Switching Power Supply Rear View see Figure 5 Figure 5 E1 Cooling Fan 1 8x8cm E2 Fan Speed Control FAN RPM HIGH 3600rpm LOW 2800 rpm Options If you want the fan to run at a high speed switch to the right otherwise switch to the left E3 Cooling Fan 2 8x8cm E4 Reset Change M...

Страница 4: ...N OFF OFF Clone OFF ON ON RAID 5 OFF ON OFF Reserved OFF OFF ON Normal Single OFF OFF OFF PS When DIP SW is RAID10 2 HDDs is RAID1 Mode and 4 HDDs is RAID10 Mode 2 1 RAID 0 for High Performance RAID 0 or Stripe is the segmentation of logically sequential data such as a single file so that segments can be assigned to multiple hard disks in a round robin fashion and thus written concurrently If any ...

Страница 5: ... disk Failure in a hard disk Host controller still could read write data Users have to replace the defect hard disk T5 will enter on line auto rebuild mode automatically 2 3 Stripe Mirror RAID 10 for High Performance and High Security T5 could be configured to support Stripe and Mirror at the same time i e RAID 10 Take four hard drives RAID 10 as an example Hard drive 0 and hard drive 1 could act ...

Страница 6: ...s at the same time 2 5 JBOD Concatenating This mode is also named Concatenating In this mode T5 will concatenate all of the hard drives into a single hard drive with larger capacity For example if three 500GB hard disks is connected to T5 in concatenating mode user will get a single hard disk with capacity of 1 500 GB 2 6 Parity Protection XOR engine in T5 generate parity block In RAID 3 mode Pari...

Страница 7: ...g any defects Users have to replace the defective hard disk T5 then will enter on line auto rebuild mode automatically 2 7 Normal Mode Single Normal mode means all of the configured hard drives exist and T5 is not in rebuild condition User can see the original hard drives from the host which supports port multiplier technology If the host does not support port multiplier then you will find only on...

Отзывы: