2009/07/16
Page
28
Venus T5
4. DIP Switch and RAID Mode cross reference
User can configure any RAID mode as below by DIP switch and apply change by Change Mode button.
Dip Switch
RAID Mode
1 2 3
RAID 0
ON
ON
ON
RAID 10
ON
ON
OFF
JBOD (Large)
ON
OFF
ON
RAID 3
ON
OFF
OFF
Clone OFF
ON
ON
RAID 5
OFF
ON
OFF
Reserved OFF OFF ON
Normal (Single)
OFF
OFF
OFF
*
PS:
When DIP-SW is RAID10, 2 HDDs is RAID1 Mode and 4 HDDs is RAID10 Mode.
4.1 RAID 0 for High Performance
RAID 0(or Stripe) is the segmentation of logically sequential data, such as a single file, so that segments
can be assigned to multiple hard disks in a round-robin fashion and thus written concurrently. (If any hard
disk becomes defective, information stored in this RAID0 will be invalid.)