![AMS AS3935 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ams/as3935/as3935_manual_2936092009.webp)
AS3935 Standard Board
ams Demo Kit Manual, Confidential
Page 9
[v1-03] 2014-Jul-08
5
GUI Description
Install the GUI and start the software. As soon as the demo board is connected the USB and
AS3935 Symbol in the corner becomes green.
The LCD will show the USB connection and the sensor is turned off.
Figure 2: GUI of the AS3935 Lightning Sensor
The following parameters can be defined on the AS3935 Lightning Sensor:
Power Down
In power down mode (R0<0>=1), the entire AS3935 is switched off. The typical current
consumption is 800nA. After power up, the TRCO is not calibrated. The calibration must be
done by the user pressing the button “Calibrate RCOs”, and respectively “Calibrate LCO” if
needed.
LNA Settings
The LNA settings have to be changed according to the location of the lightning sensor
(outdoor vs. indoor) as described in the AS3935 datasheet.
Noise Floor
The threshold for the trigger of the noise floor interrupt can be selected via this drop down
menu. A bigger value sets the threshold higher.