background image

 

ALPHA™ Wireless Data Receiver Installation Manual

 

6

 

ALPHA Big Dot® Data Receiver Setup (continued)

 

Step 4:

Get the Jumper from your Data Receiver Kit. The 
Jumper (right) is a small dark piece of plastic.

 

When installing the Jumper, be careful not to drop it inside the ALPHA Big Dot® 
case. If the Jumper falls inside, service may be required to remove it.

 

Step 5:

Locate the Two-Prong Receptacle that is below the EPROM. If there already is a 
jumper over these two prongs, then go to Step 6. Otherwise, place the Jumper 
bottom over the two prongs. Then push down until the Jumper is secure:

 

Figure 8: Where to install the Jumper.

Jumper top

Jumper bottom

STOP

Place the 
Jumper 
over these 
two prongs.

Содержание ALPHA 215

Страница 1: ...PHA 215 Big Dot 4000 Series 7000 Series and 300 Series Electronic Message Centers 1996 Adaptive Micro Systems Form No 9708 8080 8 26 96 Table of Contents Installation Instructions 1 ALPHA 215 2 ALPHA Big Dot 5 ALPHA 4000 Series 8 ALPHA 7000 Series 12 ALPHA 300 Series 16 ...

Страница 2: ...k symbol with each mention of the trademarked name the publisher states that it is using the names for editorial purposes and to the benefit of the trademark owner with no intention of improperly using the trademark BETA BRITE and BIG DOT are trademarks of Adaptive Micro Systems Inc registered in the United States Patent and Trademark Office ALPHA AlphaNET AlphaNET plus AlphaNET plus II ALPHAVISIO...

Страница 3: ...LPHA 4000 Series or 7000 Series sign when wall mounting either of these signs 1 Modular Plug Optional use Not pictured below Used to connect the 3 foot Extender Cable to the cable on the Data Receiver Figure 1 Data Receiver Kit photos not to scale If you are missing any of the above items contact your ALPHA distributor For ALPHA 215 installation go to page 2 For ALPHA Big Dot installation go to pa...

Страница 4: ...g the unit from the outlet not the back of the sign Step 2 Remove the Access Cover located on the back of the unit by sliding it towards the top of the sign Figure 2 ALPHA 215 back Step 3 After removing the Access Cover find the Two Prong Receptacle located in the compartment NOTE On some models the Two Prong Receptacle has been removed If this is the case on your sign then go to Step 6 You will N...

Страница 5: ...to drop it inside the ALPHA 215 case If the Jumper falls inside service may be required to remove it Step 5 Locate the Two Prong Receptacle that is below the EPROM If there already is a jumper over these two prongs then go to Step 6 Otherwise place the Jumper bottom over the two prongs Then push down until the Jumper is secure Figure 4 Where to install the Jumper Jumper top Jumper bottom STOP Plac...

Страница 6: ... on the back of the sign Remount the sign and restore power For Flush Wall Mounts Reinstall the original Access Cover over the compartment opening on the back of the sign Remount the sign Attach one side of the Velcro strips to the Data Receiver s Access Cover Then use the remaining Velcro to attach the Data Receiver directly to the wall next to the sign The Data Receiver MUST be installed horizon...

Страница 7: ...using an ALPHA 300 Series sign go to page 16 Step 1 Unplug the ALPHA sign from its outlet or power source Step 2 Remove the Access Cover located on the back of the unit by sliding it towards the top of the sign Figure 6 ALPHA Big Dot back Step 3 After removing the Access Cover find the Two Prong Receptacle located in the compartment Figure 7 The compartment under the Access Cover Access Cover EPRO...

Страница 8: ...to drop it inside the ALPHA Big Dot case If the Jumper falls inside service may be required to remove it Step 5 Locate the Two Prong Receptacle that is below the EPROM If there already is a jumper over these two prongs then go to Step 6 Otherwise place the Jumper bottom over the two prongs Then push down until the Jumper is secure Figure 8 Where to install the Jumper Jumper top Jumper bottom STOP ...

Страница 9: ...ble Groove Figure 9 Completed installation Step 7 For Ceiling Hanging Countertop and Wall Mounting Brackets Install the Data Receiver with its Access Cover Mount attached over the compartment opening on the back of the sign Remount the sign and restore power Step 8 After power has been restored to the sign the indicator light on the front of the Data Receiver should be on Step 9 This completes the...

Страница 10: ... 7000 Series sign go to page 12 If you re using an ALPHA 300 Series sign go to page 16 Step 1 Unplug the ALPHA sign from its outlet or power source Step 2 Remove the Access Cover located on the side of the unit by grasping the Front Tab and sliding the Access Cover off Figure 10 ALPHA 4000 Series sign front back Figure 11 Access Cover removal ALPHA 4000 Series Access Cover Front Tab Communication ...

Страница 11: ...When installing the Jumper be careful not to drop it inside the ALPHA 4000 Series case If the Jumper falls inside service may be required to remove it Step 5 Locate the Two Prong Receptacle that is below the EPROM If there already is a jumper over these two prongs then go to Step 6 Otherwise place the Jumper bottom over the two prongs Then push down until the Jumper is secure Figure 13 Installing ...

Страница 12: ...ext find the Three Prong Receptacle located below the Two Prong Receptacle If the existing jumper is not on the leftmost two pins for RS232 then remove the jumper and place it over these two pins Figure 14 Installing the Three prong jumper 232 485 Jumper Make sure the Three Prong jumper is over these two pins ...

Страница 13: ...tach one side of the Velcro strips to the Data Receiver Then use the remaining Velcro to attach the Data Receiver directly to the wall next to the sign Use the 3 foot Extender Cable and Modular Plug to mount the Data Receiver to the wall The Data Receiver MUST be installed horizontally with the LED light facing out Restore the power Step 9 After power has been restored to the sign the indicator li...

Страница 14: ... If you re using an ALPHA 4000 Series sign go to page 8 If you re using an ALPHA 300 Series sign go to page 16 Step 1 Unplug the ALPHA sign from its outlet or power source Step 2 Remove the Access Cover located on the side of the unit by unscrewing the two screws that hold it in place Figure 16 ALPHA 7000 Series sign front back ALPHA 7000 Series Access Cover Communication Ports Power supply ...

Страница 15: ... When installing the Jumper be careful not to drop it inside the ALPHA 7000 Series case If the Jumper falls inside service may be required to remove it Step 5 Locate the Two Prong Receptacle that is below the EPROM If there already is a jumper over these two prongs then go to Step 6 Otherwise place the Jumper bottom over the two prongs Then push down until the Jumper is secure Figure 18 Installing...

Страница 16: ...ext find the Three Prong Receptacle located below the Two Prong Receptacle If the existing jumper is not on the leftmost two pins for RS232 then remove the jumper and place it over these two pins Figure 19 Installing the Three prong jumper 232 485 Jumper Make sure the Three Prong jumper is over these two pins ...

Страница 17: ...tach one side of the Velcro strips to the Data Receiver Then use the remaining Velcro to attach the Data Receiver directly to the wall next to the sign Use the 3 foot Extender Cable and Modular Plug to mount the Data Receiver to the wall The Data Receiver MUST be installed horizontally with the LED light facing out Restore the power Step 9 After power has been restored to the sign the indicator li...

Страница 18: ...mmunications Port the RS232 port on the back side of the sign Figure 21 Data Receiver cable installation Step 3 Remount the sign Attach one side of the Velcro strips to the Data Receiver Then use the remaining Velcro to attach the Data Receiver directly to the wall next to the sign Use the 3 foot Extender Cable and Modular Plug to mount the Data Receiver to the wall The Data Receiver MUST be insta...

Отзывы: