![AMS AFDAU T-1 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/ams/afdau-t-1/afdau-t-1_installation-manual_2936032040.webp)
AFDAU-T1 Aerial Firefighting
Data Acquisition Unit
Installation Manual
AMS-IM-1-01 Rev. 7
22 September 2021
34
6. Once connected, the port status bar will change to a green CONNECTED
message and the current firmware version of the connected unit appears at
the bottom of the window.
7. You can read the existing configuration from the connected unit, load a
previously saved “.cfg” file or use the dropdown fields to set the configuration
as required to match your installation.
8.
To read the configuration from the connected unit, click the green “READ”
button. A progress bar will appear, followed by a dialog box telling you the
read was successful (or not).
9. Click OK and the configuration fields will be populated with the current
configuration on the connected AFDAU.