Amron 2810E-02 Скачать руководство пользователя страница 19

 

MODEL 2810E-02 USER MANUAL 

 

 

 

2810E-02-UM 

REV 2.0 

16 

19.  Perform Power On - Battery Check  

20.  Plug  2810E-02  into  AC  power  and  allow  battery  to  charge  for  4  hours 

(depending of the age of the battery and the surrounding temperature). 

4.2.2 

RECOMMENDED MAINTENANCE SCHEDULE 

The  following  sections  outline  the  recommended  scheduled  maintenance  for  the 
2810E-02. 

1. 

DAILY  MAINTENANCE  -  Wipe  off  any  accumulated  dust  or  dirt  on  the  front 
panel  or  connectors  using  a  clean,  damp  cloth.  Pay  particular  attention  to 
where  the  various  front  panel  components  attach  to  the  panel.  Inspect  the 
outer case for any damage. 

2. 

WEEKLY MAINTENANCE - Wipe off any accumulated dust or dirt on the front 
panel  or  connectors  using  a  clean,  damp  cloth.  Pay  particular  attention  to 
where the various front panel components attach to the panel. 

3. 

6 MONTH CHECK - Wipe off any accumulated dust or dirt on the front panel 
or connectors using a clean, damp cloth. Pay particular attention to where the 
various front panel components attach to the panel. Inspect the outer case for 
any damage. 

 

Inspect the PUSH-TO-TALK BUTTON, toggle switches and volume 
controls for smooth operation. 

 

Perform the 2-Wire and Full Duplex (4-Wire) system checks as described 
in section 5.1. 

4.2.3 

YEARLY CHECK 

For  maximum  service  life,  it  is  recommended  that  the  chamber  communicator  be 
sent back to Amron for a yearly check. 

4.2.4 

LONG TERM STORAGE 

If the chamber communicator is to be stored for a period greater than 30 days, it is 
recommended that it be stored in a cool dry location. Make sure that the POWER 
SWITCH is turned off during storage. The 2810E-02 should be stored plugged into 
an  AC  outlet  to  ensure  that  the  communicator  will  be  fully  charged  and  ready  to 
use when needed. 

 

 

Содержание 2810E-02

Страница 1: ...Fax 760 599 3857 Email sales amronintl com Web www amronintl com This manual and the information contained herein are provided for use as an operation and maintenance guide No license or rights to man...

Страница 2: ......

Страница 3: ...AND CHAMBER CONTROLS 6 2 1 CHAMBER CONNECTIONS 9 2 2 3 OPERATION 10 CHARGING THE BATTERY 10 3 1 INITIAL POWER ON BATTERY CONDITION CHECK 10 3 2 MODES OF OPERATION 11 3 3 4 MAINTENANCE 13 CHAMBER COMMU...

Страница 4: ...municator on the market To enjoy all the features it is important that the operator read and understand the entire manual including all warnings The 2810E 02 can operate in 2 Wire or Full Duplex 4 Wir...

Страница 5: ...MODEL 2810E 02 FRONT PANEL 1 4 All of the controls for the Model 2810E 02 are located on the front panel including the connectors for the operator handheld microphone or headset tape recorder and aux...

Страница 6: ...The Model 2401 28 is a heavy duty headset with boom microphone It comes equipped with color coded dual banana plugs that mate directly to AMCOM chamber communicators It includes a six foot 1 8 meter...

Страница 7: ...comfortable headset is designed for extended wear by chamber occupants The Model 2460 31R features an adjustable boom microphone vinyl cushioned adjustable ear pads and a spiral cord that can be exten...

Страница 8: ...3115 It also includes a sound powered phone with bracket chamber temperature probe scrubber power circuit wiring chamber environmental conditioning unit wiring and electrical penetrator adaptor all t...

Страница 9: ...turn off the speaker If the operator is using a headset it may be necessary to turn off the speaker in order to prevent acoustic feedback 2 1 3 PUSH TO TALK BUTTON This button allows the operator to...

Страница 10: ...k banana plug of the headset to this jack and the microphone red to the OPERATOR MICROPHONE jack red In this mode the operator does not have to use the PUSH TO TALK BUTTON to communicate with a chambe...

Страница 11: ...810E 02 using the Remote Push to Talk Module in 2 Wire mode 2 1 11 RECORDER OUTPUT This is a single RCA Phono jack color coded black that provides a transformer isolated output of both operator and oc...

Страница 12: ...nctions as both an output earphone and input microphone for the chamber occupants as controlled by the PUSH TO TALK BUTTON and PUSH TO TALK JACK Using this connection the chamber can be wired in eithe...

Страница 13: ...ars The BATTERY CONDITION INDICATOR will start to blink when the battery has approximately 30 remaining charge To maximize the service life the battery should be recharged as soon as possible after th...

Страница 14: ...N the occupant hears the operator Often times a 4 conductor communication cable is used with 2 wires tied together as a pair for redundancy this is still a 2 Wire system Since only one person can talk...

Страница 15: ...speaker switch to OFF adjust both volume controls to mid scale Operator and occupants use headsets and talk to each other while the operator adjusts the volume controls as below OPERATOR VOLUME While...

Страница 16: ...f that does not resolve the problem then go to the troubleshooting section to determine the cause 4 Identify the microphone and headset leads When using an Amron headset the microphone is the red bana...

Страница 17: ...phone lead into the OPERATOR HEADSET black jack and the headset lead into the CHAMBER MICROPHONE red jack 6 Don the headset Talk into the microphone while pressing the PUSH TO TALK BUTTON You should b...

Страница 18: ...f unit 3 Disconnect all cables 4 Remove 4 ea pan head Phillips screws 2 ea on each side of AMRON INTERNATIONAL 2 ea on each side of MODEL 2810E 02 5 Lift the 2810E 02 out of chamber control panel 6 Re...

Страница 19: ...us front panel components attach to the panel 3 6 MONTH CHECK Wipe off any accumulated dust or dirt on the front panel or connectors using a clean damp cloth Pay particular attention to where the vari...

Страница 20: ...battery Check the battery per section 5 3 1 If the battery is good then disconnect any chamber wiring and perform the communicator check out procedure per section 5 1 If the battery and battery connec...

Страница 21: ...the problem then the operator headset may be wet or defective If these steps have not solved the problem then disconnect the chamber wiring and perform the communicator check out procedure per sectio...

Страница 22: ...tions cable In a good cable with all the wires open not connected the resistance between any two wires should be greater than 10 Meg Ohms Over time the cable can be damaged and this resistance drops t...

Страница 23: ...al details of the chamber communication unit The corresponding parts lists for each drawing are detailed in the parts lists section or are included as part of the drawing All drawings are at their cur...

Страница 24: ...MODEL 2810E 02 USER MANUAL 2810E 02 UM REV 2 0 21 FRONT PANEL PARTS LOCATOR MODEL 2810E 02 5 1...

Страница 25: ...MODEL 2810E 02 USER MANUAL 2810E 02 UM REV 2 0 22 MOUNTING DETAIL MODEL 2810E 02 5 2...

Страница 26: ...Replacement Parts Contact Amron International Inc 1380 Aspen Way Vista California 92081 U S A Telephone 760 208 6500 Fax 760 599 3857 Email sales amronintl com Web www amronintl com When ordering repl...

Страница 27: ...01 01 Jack RCA Red Panel Mount 52 160 1001 02 Jack RCA White Panel Mount N S 190 0101 00 Power Supply N S 2890 05 Battery Rechargeable 12V N S 2405 28 Microphone Handheld w PTT Switch N S 2810E 02 UM...

Страница 28: ...ccident repair or alterations SERVICE POLICY For technical assistance or to request a repair please complete one of the following Amron Communicator Repair https www amronintl com communicator repair...

Отзывы: