13
Manual Scan
1. Press
button to turn on the Analyzer.
2. Properly connect the pair of Kelvin clips to the solar panel and the
Analyzer. The red Kelvin clip is for positive pole and the black Kelvin clip
for negative pole.
3. Press
button to enter the SETUP menu: (Type in the current range
for scanning)
Current Range of Scan begin: 200mA
Current Range of Scan end: 548mA
After setting up the current range, press
button again to exit the
SETUP menu.
Note:
If the “Current Range of Scan begin” is over “Ishort”, then the
scanning will not be performed and no result will come out.
4. Press
(SCAN) button to start MANUAL SCAN. The analyzer run
simulation from the BEGIN value to END value, and draw I-V / V-I curve
and P-V / P-I curve in LCD. Users can move the cursor to review each
individual values along the curve.
After the scanning is finished, the result will come out like below.
�
WARNING!
There is a time delay before the unit performs the “Manual Scan”. This
time delay allows the light source to be turned on before “Manual Scan”
starts. Time delay can be set in the SETUP menu.
Содержание SOLAR-500
Страница 1: ...Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso SOLAR 500 Solar Analyzer ...
Страница 4: ...SOLAR 500 Solar Analyzer 1 2 3 4 5 7 9 11 12 13 14 15 16 17 18 19 20 10 6 8 A Front Panel ...
Страница 10: ...4 Example B Maintenance of Solar Panels Abnormal I V Curve Cells at the corner of solar panel are defected ...
Страница 15: ...9 Connecting Diagram Kelvin Clip Connecting Diagram Alligator Clip Connecting Diagram ...
Страница 29: ...23 Location of Fuse Unscrew and remove the battery cover and the back cover ...
Страница 39: ......