18
SPECIFICATION
Ambient temperature: 23°C ±5°C (73.4°F ±9°F); Relative temperature:
≤
75%
Accuracy: ±(% of r digits)
Maximum voltage between input terminal and earth ground:
AC 1000Vrms or DC 1000V
�
Fuse for mA µA input: F1 0.5A H 1000V fast-fuse, (
Φ
6×32)mm
�
Fuse for 10A input: F2 11A H 1000V fast-fuse, (
Φ
10×38)mm
Maximum display: Digital 5999 counts, updates 3/sec.
Analog pointer display: 61 segments. Updates 20 times/sec.
Over-range indication: OL
Range: Automatic and Manual
Altitude: Operating
≤
2000m
Operating temperature: 0°C~+40°C (32°F~104°F)
Relative humidity: 0°C~+30°C (32°F~86°F)
≤
75%; +30°C~+40°C (86°F~104°F)
≤
50%
Storage temperature: -10°C~+50°C (14°F~122°F)
Electromagnetic compatibility: In an RF filed of 1V/m = Specified accuracy ± 5%
Battery: 9V, 6F22, NEDA1604 or equivalent
Low battery indication:
Dimensions (L x W x H): 182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
Weight: Approx. 354g (0.78 lb) with batteries installed
1. DC Voltage Measurement
Range
Resolution
Accuracy
600.0mV
0.1mV
±(0.5%+3 LSD)
6.000V
1mV
±(0.5%+2 LSD)
60.00V
10mV
600.0V
100mV
1000V
1V
±(1.0%+2 LSD)
Input impedance: Around 10M
Ω
;
Overload protection: ±1000V
Содержание AM-540
Страница 2: ......
Страница 31: ...25 F1 9 V b a tt e ry F2 ...
Страница 32: ......
Страница 61: ...25 F1 P ile 9 V F2 ...
Страница 62: ......
Страница 91: ...25 F1 9 V B at te rie F2 ...
Страница 92: ......
Страница 121: ...25 F1 P ila 9 V F2 ...
Страница 122: ......
Страница 151: ...25 F1 B a te rí a 9 V F2 ...
Страница 152: ......
Страница 181: ...25 F1 B a tt e ri 9 V F2 ...
Страница 182: ......