Appendix B
I/O Interface Board
34
QuickStart Guide
CoreModule 800
Miscellaneous Components
Table B-13 list the helpful components on the I/O Interface Board.
Table B-13. Miscellaneous Components
Component
Description
Battery
Battery Socket (BAT1) – Supports external Lithium (3.0V) battery for the Real
Time Clock on CoreModule 800.
Fuse (F1)
Auto-reset, 1.5 Amp shared fuse for keyboard and mouse.
LED (D1)
Green Hard Disk Drive Activity LED (D1) – Indicates activity on the IDE connector
(J6) located on the CoreModule 800.
•
Steady Green = No IDE devices connected.
•
Flashing Green = IDE device activity
•
Steady Off = IDE device connected, but no activity.
LED (D3)
Yellow Power On LED (D3) – Indicates power state of the CoreModule 800.
•
Steady Yellow = Power On
•
Steady Off
=
Power Off
Switch (SW1)
Power Button Switch – Provides external Power on signal (ground) through the
interface to CoreModule 800 on pin J5-34.
Switch (SW2)
Reset Switch – Provides external reset signal (ground) to CoreModule 800 on pin
J5-33.