User Manual of
C20-GSM
Repeaters
6
3.6
Appearance Diagram
3.7
Ports
Страница 1: ...User Manual of C10 Series Repeaters ...
Страница 2: ...AGRAM 4 3 4 ELECTRICAL SPECIFICATION 5 3 5 MECHANICAL SPECIFICATION 5 3 6 APPEARANCE DIAGRAM 6 3 7 PORTS 6 CHAPTER 4 INSTALLATION 7 4 1 INSTALLATION REQUIREMENTS 7 4 2 INSTALLATION 8 4 3 CONNECTION 10 5 1 POWER SUPPLY CONNECTION 11 5 2 PERFORMANCE SETTING 11 CHAPTER 6 PRODUCE MAINTENANCE 12 6 1 OPERATION AND MAINTENANCE 12 6 2 EMERGENCY DEALING 13 6 3 MAINTAINING DIRECTIONS 13 ...
Страница 3: ... power in advance Only the professional can operate electrified 3 Do not dismantle machine maintain or displace accessories by yourself because in this way the equipment may be damaged or even get an electric shock 4 Do not open the repeaer touch the module of repeater even not to open the cover of module to touch the electronic component the components will be damaged due to electrostatic 5 Pleas...
Страница 4: ...reas Wide band consumer repeaters mainly applied in covering small blind and weak zones C10 series repeater is a good choice for weak signal area of GSM system such as VIP rooms offices houses restaurants apartments packing etc 3 1Application C10 series repeater enhances consumer satisfaction greatly with its integrated design compact size easy engineering and rapid installation and debugging ...
Страница 5: ... V 2A 3 2 Features Compact design and light weight cost effectiveness LED indication for operation status Selective band function to work on GSM support Low power consumption Low interference Applicable to In Building with medium or small size with Maximum coverage up to 1200 Square meters such as VIP room office house restaurants apartments parking ALC to limit output power at specified power lev...
Страница 6: ... 1GHz 12 75GHz 40dBm 3KHz Noise Figure 6dB VSWR 2 Group Delay 0 5µs Weight 1 5Kg Dimensions D x W xH 209 133 41mm Environment Conditions IP40 Impedance 50 Ohms Power Supply AC 120V DC 9V2A Adapter Working Temperature 25 to 55 Humidity 5 95 2 Alarm specification Power LED DC ON OFF ALC 1 5dB orange LED indication Alarm LED ALC 20 25dB red 3 5Mechanical Specification Environment Conditions IP40 Weig...
Страница 7: ...User Manual of C20 GSM Repeaters 6 3 6 Appearance Diagram 3 7 Ports ...
Страница 8: ...1 Installation requirements C10 series repeaters are mainly applied as indoor coverage GSM system After connection of equipment and antenna the distance of them should be keep as far away as possible it s better that there is a wall as the obstruct between them ...
Страница 9: ...n the place that is not easy to be reached by irrelevant people Install at the place that is convenient for power supply and cabling Avoid heat source and moist environment Power supply requirement AC power supply of 9V 2A Installation 4 2 Installation component 1 ...
Страница 10: ...User Manual of C20 GSM Repeaters 9 installation step 1 Installation step 2 ...
Страница 11: ...1 onto the wall 2 Put the component 2 into component 1 4 3 Connection Connection of RF cable Input Port put the antenna outdoor and try to put on the place where there is strong signal then connect one adapter to BTS of equipment and assure good connection Power supply connection Please use three pin plug to assure good grounding Chapter 5 Repeater setting component 1 component 2 ...
Страница 12: ...arity green attention Input signals may be not enough Meaning overloading or self oscillation strong input signals red Attention cut the connection of equipment and service antenna then connect the MS port to load if the red light changes to green or orange which means the isolation of donor antenna and service antenna is not enough then please adjust the isolation If the red light still turning o...
Страница 13: ...ng Chapter 6 Produce Maintenance 6 1 Operation and maintenance Power supply Please make sure the voltage and frequency comply with the repeater requirement Component replacement Please do not maintain or replace components by yourself otherwise may get an electric shock Only the authorised professional can maintain and replace the components POutput Power Pmax Pinput Power VATT Green Linear amplif...
Страница 14: ...t normal overheating abnormal smelling abnormal sundries Closet damage performance decreasement near to fire flooding 6 3 Maintaining directions Please check the booster step by step according to below process to find out the problem with the repeater Abnormal performance Green Red Off LED check Feeder system inspection Improve the feeder system Isolation inspection Power supply inspection Improve...
Страница 15: ...5V 265V 50 60Hz specification Power LED DC ON OFF ALC 1 5dB orange ALC 20 25dB red LED indication Alarm LED Weight Environment Conditions DC Supply 2 Alarm Spurious Emission Noise Figure VSWR Group Delay Automatic Level Control Gain Flatness Output Power Intermodulation Products C10 GSM Electrical specification Frequency Range Max Gain GSM900 UL 890 915MHz DL 935 960MHz ...
Страница 16: ...NION Issued by Notified Body 1177 TIMCO Engineering Inc Date October 9 2008 Opinion number TCF 2300CC8 Original TCF 2248CC8 On behalf of The President of TIMCO Engineering Inc Signature Name Bruno Clavier The device shall be marked as follows THIS STATEMENT OF OPINION HAS NO ADDENDUM Based on the evidence presented in the Technical Construction File TIMCO Engineering Inc as appointed Notified Body...
Страница 17: ...quency band UL 890 915MHz DL 935 960MHz Modulation GMSK CDMA Antenna type Integral RF output power Cond UL 5dBm DL 10dBm Frequency band UL 1710 1785MHz DL 1805 1880MHz Modulation GMSK CDMA Antenna type Integral TIMCO ENGINEERING INC P O BOX 370 NEWBERRY FLORIDA 32669 Telephone 1 888 472 2424 Fax 1 352 472 2030 E mail tei timcoengr com ...