Model 20T4G18
CAUTION:
Do not adjust 20-turn pot R11; its function is to set the foldback RF
output level, and it is calibrated at the factory.
3.8 REMOTE IEEE-488 OPERATION
The TWTA is provided with a communication interface that conforms electrically to the IEEE-488 standard.
It permits remote emulation of OPERATE, STANDBY, and RESET push-buttons as well as access to
parameter measurements, system faults, gain adjustment, and control unit status. The following tables
summarize the commands and the return codes.
Table 3. Catalog of IEEE-488 Commands
18
Rev B
Command Function
Units
Response
format
RDSTAT
Returns status code of processing of previous command (see Table 4)
STATUS=[ ]
RDFLT
Returns system fault code (see Table 5)
flt=[ ]
OPERATE;
Emulates OPERATE push-button
STANDBY;
Emulate STANDBY push-button
POWER:OFF;
Emulate STANDBY push-button
RESET;
Emulates RESET softkey
RDS/N
Returns serial number
s/n=[ ]
RDCONHR
Returns console hours
ConHr=[ ]
RDRFHR
Returns RF hours
RfHr=[ ]
RDEK
Returns cathode voltage
KV
Ek=[ ]
RDEB
Returns collector voltage
KV
Eb=[ ]
RDEF
Returns heater voltage
V
Ef=[ ]
RDIF
Returns heater current
A
If=[ ]
RDIW
Returns helix current
mA
Iw=[ ]
RDTMPTWTF
Returns TWT temp (°F)
°F
TWTF=[ ]F
RDTMPTWTC
Returns TWT temp (°C)
°C
TWTC=[ ]C
RDTMPPSF
Returns power supply temp (°F)
°F
PSF=[ ]F
RDTMPPSC
Returns power supply temp (°C)
°C
PSC=[ ]C
RDTWTOTF
Returns TWT overtemp warning setpoint (°F)
°F
TWTOTF=[ ]F
STWTOTF
Sets TWT overtemp warning setpoint (°F)
°F
RDTWTOTC
Returns TWT overtemp warning setpoint (°C)
°C
TWTOTC=[ ]C
STWTOTC
Sets TWT overtemp warning setpoint (°C)
°C
RDPSOTF
Returns power supply overtemp warning setpoint (°F)
°F
PSOTF=[ ]F
SPSOTF
Sets p. s. overtemp warning setpoint (°F)
°F
RDPSOTC
Returns p. s. overtemp warning setpoint (°C)
°C
PSOTC=[ ]C
SPSOTC
Sets p. s. overtemp warning setpoint (°C)
°C
RDIWOC
Returns helix overcurrent warning setpoint
mA
IwOC=[ ]
SIWOC
Sets helix overcurrent warning setpoint
mA
RDLOGIC
Returns logic state code (see Table 6)
Sys=[ ]
RDA
Returns gain
%
A=[ ]
SA Sets
gain
%
http://www.Datasheet4U.com
Содержание 200T4G18
Страница 2: ...Model 20T4G18 2 http www Datasheet4U com...
Страница 4: ...Model 20T4G18 4 http www Datasheet4U com...
Страница 6: ...Model 20T4G18 2 http www Datasheet4U com...
Страница 8: ...Model 20T4G18 4 http www Datasheet4U com...
Страница 38: ...Model 20T4G18 28 Rev B http www Datasheet4U com...
Страница 42: ...Model 20T4G18 32 Rev B http www Datasheet4U com...
Страница 44: ...Model 20T4G18 34 Rev B http www Datasheet4U com...
Страница 58: ...Model 20T4G18 48 Rev B http www Datasheet4U com...
Страница 60: ...http www Datasheet4U com...