Chapter 1

Getting Started

PXI Peripheral Slots

There are four PXI peripheral slots which will accept PXI or CompactPCI 
peripherals: slot 2, slot 6, slot 7, and slot 8. These slots are on the 
backplane’s 32-bit PCI bus. These slots offer full PXI functionality, but 
have no PXI Express features. The 64-bit PCI signals on the P2 connectors 
are not connected.

System Timing Slot

The System Timing Slot is slot 4. The system timing slot will accept the 
following peripheral modules:

A PXI Express System Timing Module with x4 or x1 PCI Express link 
to the system slot.

A PXI Express Peripheral with x4 or x1 PCI Express link to the system
slot.

A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express
link to the system slot.

The system timing slot has 3 dedicated differential pairs (PXIe_DSTAR) 
connected from the TP2 connector to the XP3 connector for each hybrid 
peripheral slot, as well as routed back to the XP3 connector of the system 
timing slot as shown in Figure 1-3. The PXIe_DSTAR pairs can be used for 
high-speed triggering, synchronization and clocking. Refer to the 

PXI Express Specification

 for details.

The system timing slot also has a single-ended (PXI Star) trigger connected 
to every slot. Refer to Figure 1-3 for details.

The system timing slot has a pin (PXI_CLK10_IN) through which a system 
timing module may source a 10MHz clock to which the backplane will 
phase-lock. Refer to the 

System Reference Clock

 section for details.

The system timing slot has a pin (PXIe_SYNC_CTRL) through which a 
system timing module can control the PXIe_SYNC100 timing. Refer to the 

PXI Express Specification

 and the 

PXIe_SYNC_CTRL

 section of this 

chapter for details.

Manual

Sales:

 

+44 (0) 1273 570 220   

Website:

 www.amplicon.com   

Email:

 [email protected]

       IT and Instrumentation for industry

 Amplicon.com

Содержание NATIONAL INSTRUMENTS PXI Express NI PXIe-1062Q

Страница 1: ...ess TM NI PXIe 1062Q User Manual NI PXIe 1062Q User Manual April 2012 371843D 01 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 2: ...Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 3: ...ormation retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other intellectual property laws Where NI software may be used to reproduce software or other materials belonging to others y...

Страница 4: ...SIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION INCLUDING WITHOUT LIMITATION THE A...

Страница 5: ... 1 8 System Timing Slot 1 8 PXI Local Bus 1 9 PXI Trigger Bus 1 10 System Reference Clock 1 10 PXIe_SYNC_CTRL 1 13 Chapter 2 Installation and Configuration Safety Information 2 1 Chassis Cooling Considerations 2 2 Providing Adequate Clearance 2 2 Chassis Ambient Temperature Definition 2 5 Setting Fan Speed 2 5 Installing Filler Panels 2 5 Installing Slot Blockers 2 5 Rack Mounting 2 5 Connecting S...

Страница 6: ... Interval 3 1 Preparation 3 1 Cleaning 3 1 Interior Cleaning 3 2 Exterior Cleaning 3 2 Cleaning the Fan Filters 3 2 Resetting the AC Mains Circuit Breaker 3 2 Replacing the Modular Power Supply 3 3 Removal 3 3 Installation 3 4 Configuration 3 4 Connecting Safety Ground 3 4 Connecting to Power Source 3 4 Appendix A Specifications Appendix B Pinouts Appendix C Technical Support and Professional Serv...

Страница 7: ... to the Read Me First Safety and Electromagnetic Compatibility document shipped with the product for precautions to take bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes variables emphasis a cross reference or an introduction to a key concept Italic text also denote...

Страница 8: ...dard for Additional Mechanical Specifications for Microcomputers Using IEEE 1101 1 Equipment Practice PICMG EXP 0 R1 0 CompactPCI Express Specification PCI Industrial Computers Manufacturers Group PCI Express Base Specification Revision 1 1 PCI Special Interest Group PXI 5 PXI Express Hardware Specification Revision 2 0 PXI Systems Alliance Manual Sales 44 0 1273 570 220 Website www amplicon com E...

Страница 9: ...d components If damage appears to have been caused during shipment file a claim with the carrier Retain the packing material for possible inspection and or reshipment What You Need to Get Started The NI PXIe 1062Q chassis kit contains the following items NI PXIe 1062Q chassis Filler panels AC power cable refer to Table 1 1 for AC power cables NI PXIe 1062Q User Manual Software media with PXI Platf...

Страница 10: ...hassis include the following High Performance for Instrumentation Requirements Up to 1 GB s single direction per PXI Express slot dedicated bandwidth x4 PCIe 353 9 W available power for 0 to 55 C 30 W per slot cooling meets increased PXI Express cooling requirements Low jitter internal 10 MHz reference clock for PXI slots with 25 ppm stability Low jitter internal 100 MHz reference clock for PXI Ex...

Страница 11: ...eliability Field replaceable power supply shuttle Multi Chassis Support PXI Express System Timing Slot for tight synchronization across chassis Rear CLK10 I O connectors Switchless CLK10 routing Optional Features Front and rear rack mount kits Replacement power supply shuttle EMC filler panels Slot blockers for improved cooling performance Factory installation services Manual Sales 44 0 1273 570 2...

Страница 12: ...ower Inhibit Switch 2 Power Inhibit Switch LED 3 Removable Feet 4 Chassis Carry Handle 5 Chassis Model Name 6 Backplane Connectors 7 System Controller Expansion Slots 8 PXI Express System Controller Slot 9 PXI Express Hybrid Peripheral Slots 10 PXI Express System Timing Slot 11 PXI Peripheral Slot 12 PXI Filler Panels NI PXIe 1062Q 2 1 3 4 8 3 3 5 6 11 11 9 10 9 12 7 Manual Sales 44 0 1273 570 220...

Страница 13: ...Inhibit and Voltage Monitoring Connector 8 Air Filter Retainer 9 Air Filter Retainer Screw 10 Power Supply Shuttle ID Label 11 Fan Speed Selector Switch 12 Inhibit Mode Selector Switch 13 Power Supply Shuttle Handle 2x 14 Power Supply Shuttle Mounting Screws 8x 2 3 9 7 14 13 1 8 5 6 4 10 11 12 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation f...

Страница 14: ...ck Mount Kit Components Slot Blockers Optional slot blocker kits are available from National Instruments for improved thermal performance when all slots are not used NI PXIe 1062Q Chassis Backplane Overview This section provides an overview of the backplane features for the NI PXIe 1062Q chassis Interoperability with CompactPCI The design of the NI PXIe 1062Q provides you the flexibility to use th...

Страница 15: ...t be in the Default position for the system controller to have control of the power supply Refer to the Inhibit Mode Switch section of Chapter 2 Installation and Configuration for details about the Inhibit Mode switch Hybrid Peripheral Slots The chassis provides two hybrid peripheral slots as defined by the PXI 5 PXI Express Hardware Specification slot 3 and slot 5 A hybrid peripheral slot can acc...

Страница 16: ...connected from the TP2 connector to the XP3 connector for each hybrid peripheral slot as well as routed back to the XP3 connector of the system timing slot as shown in Figure 1 3 The PXIe_DSTAR pairs can be used for high speed triggering synchronization and clocking Refer to the PXI Express Specification for details The system timing slot also has a single ended PXI Star trigger connected to every...

Страница 17: ...e right local bus signals from slot 8 are not routed anywhere Local bus signals may range from high speed TTL signals to analog signals as high as 42 V PXI Star 0 PXI Star 2 PXI Star 3 PXI Star 5 PXI Star 6 PXI Star 1 PXI Star 4 P1 P2 P1 P2 P1 P2 P1 XP3 XP4 P1 P2 XP3 XP2 XP1 XP4 P1 XP3 XP4 XP3 TP2 XP4 Slot 1 System Controller Slot Slot 2 PXI Peripheral Slot Slot 3 Hybrid Peripheral Slot Slot 4 Sys...

Страница 18: ...y driven to each peripheral slot and PXIe_CLK100 and PXIe_SYNC100 to the hybrid slots and system timing slot An independent buffer having a source impedance matched to the backplane and a skew of less than 250 ps between slots drives PXI_CLK10 to each peripheral slot Refer to Figure 1 5 for the routing configuration of PXI_CLK10 You can use this common reference clock signal to synchronize multipl...

Страница 19: ...ential pair must be terminated on the peripheral with LVPECL termination for the buffer to drive PXIe_SYNC100 so that when there is no peripheral or a peripheral that does not connect to PXIe_SYNC100 there is no clock being driven on the pair to that slot Figure 1 5 Distribution of PXI_CLK10 PXIe_CLK100 and PXIe_SYNC100 PXI_CLK10 PXI_CLK10_IN PXIe_CLK100 PXIe_SYNC100 System Controller Slot 1 PXI P...

Страница 20: ...ndix A Specifications for the specification information for an external clock provided on the PXI_CLK10_IN pin of the system timing slot You also can drive a 10 MHz clock on the 10 MHz REF IN connector on the rear of the chassis When a 10 MHz clock is detected on this connector the backplane automatically phase locks the PXI_CLK10 PXIe_CLK100 and PXIe_SYNC100 signals to this external clock and dis...

Страница 21: ...ill maintaining its phase relationship to PXI_CLK10 The value for n may be set to any positive integer from 1 to 255 The system timing slot has a control pin for PXIe_SYNC100 called PXIe_SYNC_CTRL for use when n 1 Refer to Table B 6 XP3 Connector Pinout for the System Timing Slot for system timing slot pinout Refer to Appendix A Specifications for the PXIe_SYNC_CTRL input specifications Table 1 2 ...

Страница 22: ... restart This will allow several chassis to have their PXIe_SYNC100 in phase with each other Refer to Figure 1 7 for timing details with this method Figure 1 7 PXIe_SYNC100 at 3 33 MHz Using PXIe_SYNC_CTRL as Restart PXI_CLK10 PXIe_SYNC_CTRL PXIe_SYNC100 SYNC100 Divider Restarted Here Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for indust...

Страница 23: ...be connected during use of this equipment to minimize shock hazards Refer to the Connecting Safety Ground section for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must not remove protective covers when operating or servicing the chassis Adjustments and service to internal components must be undertaken by qualified service technicians During servi...

Страница 24: ...cooling clearances as outlined in the following sections Providing Adequate Clearance The primary cooling exhaust vent for the NI PXIe 1062Q is on the top of the chassis The primary intake vent is on the rear of the chassis where the air is filtered as it enters the power supply shuttle The secondary intake and exhaust vents are located along the sides of the chassis Adequate clearance between the...

Страница 25: ...figuration Figure 2 1 NI PXIe 1062Q Cooling Clearances 1 75 44 45 NI PXIe 1062Q 1 75 44 45 3 00 76 20 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 26: ...62Q Vents 1 Primary Air Exhaust Vent 2 Air Filter 3 Primary Air Intake Vent 4 Secondary Air Intake Exhaust Vents 2 3 4 1 NI PXIe 1062Q Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 27: ...iew of the NI PXIe 1062Q Chassis to locate the fan speed selector switch Select High for maximum cooling performance or Auto for improved acoustic performance When set to Auto the fan speed is determined by chassis intake air temperature Installing Filler Panels To maintain proper module cooling performance install filler panels provided with the chassis in unused or empty slots Secure with the ca...

Страница 28: ...n with a yellow stripe or must be noninsulated bare 2 Attach the opposite end of the wire to permanent earth ground using toothed washers or a toothed lug Connecting to Power Source Cautions Do not install modules prior to performing the following power on test To completely remove power you must disconnect the AC power cable Attach input power through the rear AC inlet using the appropriate AC po...

Страница 29: ...ctrical damage while you install the system controller 2 Install the system controller into the system controller slot slot 1 indicated by the red card guides by first placing the system controller PCB into the front of the card guides top and bottom Slide the system controller to the rear of the chassis making sure that the injector ejector handle is pushed down as shown in Figure 2 3 Figure 2 3 ...

Страница 30: ...hat the system controller boots If the system controller does not boot refer to your system controller user manual Figure 2 4 shows a PXI Express system controller installed in the system controller slot of a NI PXIe 1062Q chassis You can place CompactPCI CompactPCI Express PXI or PXI Express modules in other slots depending on the slot type Figure 2 4 NI PXI Express System Controller Installed in...

Страница 31: ...nect the AC power source to the PXI Express chassis before installing the module The AC power cord grounds the chassis and protects it from electrical damage while you install the module 2 Ensure that the chassis is powered off 3 Install a module into a chassis slot by first placing the module card PCB into the front of the card guides top and bottom as shown in Figure 2 5 Slide the module to the ...

Страница 32: ...hing the chassis is powered on and operating normally If the inhibit switch LED is flashing green the air intake temperature has exceeded the chassis operating range 1 Peripheral Module Front Panel Mounting Screws 2x 2 NI PXI Express System Controller 3 NI PXIe 1062Q Chassis 4 Injector Ejector Rail 5 Injector Ejector Handle 6 PXI Peripheral Module 3 2 4 NI PXIe 1062Q 1 6 5 Manual Sales 44 0 1273 5...

Страница 33: ...odules from damage due to overheating Remote Voltage Monitoring and Control The NI PXIe 1062Q chassis supports remote voltage monitoring and inhibiting through a female 9 pin D SUB DB 9 connector located on the rear panel Table 2 1 shows the pinout of the 9 pin D SUB DB 9 connector Table 2 1 Remote Inhibit and Voltage Monitoring Connector Pinout DB 9 Pin Signal 1 Logic Ground 2 5 VDC 3 Reserved 4 ...

Страница 34: ...monitoring connector Connect the reference lead of the voltmeter to one of the ground pins Compare each voltage reading to the values listed in Table 2 2 Note Use the rear panel 9 pin D SUB connector to check voltages only Do not use the connector to supply power to external devices If the voltages fall within the specified ranges the chassis complies with the CompactPCI voltage limit specificatio...

Страница 35: ...onitoring connector to power off the chassis To remotely power off the chassis connect the Inhibit pin pin 5 to a Logic Ground pin pin 1 or 9 As long as this connection exists the chassis will remain off standby when you remove this connection the chassis turns on Note For the Remote Inhibit signal to control the On Off standby state of the chassis the Inhibit Mode switch must be in the Manual pos...

Страница 36: ...xiesys ini and pxisys ini file which define your PXI system parameters MAX also provides an interface to route and reserve triggers so dynamic routing through drivers such as DAQmx avoids double driving and potentially damaging trigger lines For more information about routing and reserving PXI triggers refer to KnowledgeBase 3TJDOND8 at ni com support The configuration steps for single or multiple...

Страница 37: ... chassis and system modules must document the capabilities of their products PXI Express devices must provide a driver and ini file for identification These files are provided as part of the PXI Platform Services software included with your system controller The minimum documentation requirements for PXI 1 are contained in ini files which consist of ASCII text System integrators configuration util...

Страница 38: ... called pxisys ini PXI System Initialization The system controller manufacturer either provides a pxisys ini file for the particular chassis model that contains the system controller or provides a utility that can read an arbitrary chassis ini file and generate the corresponding pxisys ini file System controllers from NI provide the pxisys ini file for the NI PXIe 1062Q chassis so you should not n...

Страница 39: ...lectromagnetic Compatibility document included with your kit before attempting any procedures in this chapter Caution Many components within the chassis are susceptible to static discharge damage Service the chassis only in a static free environment Observe standard handling precautions for static sensitive devices while servicing the chassis Always wear a grounded wrist strap or equivalent while ...

Страница 40: ...ents Cleaning the Fan Filters Dirty fan filters can dramatically affect the cooling performance of a NI PXIe 1062Q chassis Clean the filters whenever they become visibly dirty You can easily remove the chassis air filters from the rear of the chassis by removing the filter retainer To remove the filter retainer loosen the retainer screw The filter cover and retainer are shown in Figure 1 2 Rear Vi...

Страница 41: ...oubleshooting information Replacing the Modular Power Supply This section describes how to remove configure and install the AC power supply shuttle in the NI PXIe 1062Q chassis Cautions Disconnect the power cable prior to replacing the power supply Do not attempt to use a power supply shuttle from another chassis such as the NI PXI 1042 Doing so may damage your chassis and the power supply shuttle...

Страница 42: ...pening on the rear of the chassis Replace and tighten the eight screws with a Phillips screwdriver Configuration The fan speed selector switch is on the rear panel of the power supply shuttle Refer to Figure 1 2 Rear View of the NI PXIe 1062Q Chassis to locate the fan speed selector Select High for maximum cooling performance recommended or Auto for quieter operation Set the Inhibit Mode switch to...

Страница 43: ...ing voltage range1 90 to 264 VAC Input frequency 50 60 Hz Operating frequency range1 47 to 63 Hz Input current rating 8 A Over current protection 10 A circuit breaker Line regulation 3 3 V 0 2 5 V 0 1 12 V 0 1 Efficiency 70 typical 1 The operating range is guaranteed by design Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Ampli...

Страница 44: ...apacity IMP Note Maximum total usable power is 353 6 W Backplane slot current capacity Voltage Maximum Current 3 3 V 32 A 5 V 30 A 12 V 25 A 12 V 1 5 A 5 VAUX 2 A Slot 5 V V I O 3 3 V 12 V 12 V 5 VAUX System Controller Slot 15 A 15 A 30 A 1 A System Timing Slot 6 A 4 A 1 A Hybrid Peripheral Slot with PXI 1 Peripheral 6 A 5 A 6 A 1 A 1 A Hybrid Peripheral Slot with PXI 5 Peripheral 6 A 4 A 1 A PXI ...

Страница 45: ...ipple and noise 20 MHz bandwidth Over current protection All outputs protected from short circuit and overload with automatic recovery Over voltage protection 3 3 V and 5 V Clamped at 20 to 30 above nominal output voltage Power supply shuttle MTTR Replacement in under 5 minutes Voltage Load Regulation 3 3 V 5 12 V 5 5 V 5 12 V 5 Voltage Maximum Ripple and Noise 3 3 V 50 mVpp 12 V 50 mVpp 5 V 50 mV...

Страница 46: ...ly cooling intake Right side of chassis Power supply cooling exhaust Left side of chassis Environmental Maximum altitude 2 000 m 800 mbar at 25 C ambient Pollution Degree 2 For indoor use only Operating Environment Ambient temperature range 0 to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 low temperature limit and MIL PRF 28800F Class 2 high temperat...

Страница 47: ...0F Class 2 limits Random Vibration Operating 5 to 500 Hz 0 3 grms Nonoperating 5 to 500 Hz 2 4 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 Acoustic Emissions Sound Pressure Level at Operator Position Tested in accordance with ISO 7779 Meets MIL PRF 28800F requirements Auto fan up to 30 C ambient 43 6 dBA High fan 62 dBA...

Страница 48: ...ns ICES 001 Class A emissions Note For the standards applied to assess the EMC of this product refer to the Online Product Certification section Note For EMC compliance operate this device with shielded cabling CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electromagnetic Compatibility Di...

Страница 49: ...about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Backplane Size 3U sized one system slot with three system expansion slots and seven peripheral slots Compliant with IEEE 1101 10 mechanical packaging PXI Express Specification compliant Accepts both PXI Express and CompactP...

Страница 50: ... Reference Clock PXIe_CLK100 and PXIe SYNC100 Maximum slot to slot skew 100 ps Accuracy 25 ppm max guaranteed over the operating temperature range Maximum jitter 3 ps RMS phase jitter 10 Hz 12 kHz range 2 ps RMS phase jitter 12 kHz 20 MHz range Duty factor for PXIe_CLK100 45 55 Absolute differential voltage When terminated with a 50 Ω load to 1 30 V or Thévenin equivalent 400 1000 mV Single ended ...

Страница 51: ...y 10 MHz 100 PPM Input amplitude Rear panel BNC 200 mVPP to 5 VPP square wave or sine wave System timing slot PXI_CLK10_IN 5 V or 3 3 V TTL signal Rear panel BNC input impedance 50 Ω 5 Ω Maximum jitter introduced by backplane 1 ps RMS phase jitter 10 Hz 1 MHz range PXIe_SYNC_CTRL VIH 3 0 5 5 V VIL 0 0 8 V PXI Star Trigger Maximum slot to slot skew 250 ps Backplane characteristic impedance 65 Ω 10 ...

Страница 52: ... Support For more information about this chassis support of hardware modules with 64 bit DMA and or 32 bit DMA with PAE mode please visit ni com info and enter the Info Code PXI64HANG Mechanical Overall dimensions Standard chassis Height 6 97 in 177 1 mm Width 10 68 in 271 4 mm Depth 15 61 in 396 5 mm Note 0 57 in 14 5 mm is added to height when feet are installed When tilted with front feet exten...

Страница 53: ... for the installation of the optional rack mount kits You can install those kits on the front or rear of the chassis depending on which end of the chassis you want to face toward the front of the instrument cabinet Notice that the front and rear chassis mounting holes size M4 are symmetrical Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for...

Страница 54: ...28 15 61 396 5 6 97 177 1 0 57 14 5 3 542 89 97 1 844 46 84 1 40 35 6 1 823 46 30 1 68 42 6 Front of PXI Card 2 13 54 2 Dimensions are in inches millimeters NI PXIe 1062Q 0 30 7 25 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 55: ... Figure A 2 NI PXIe 1062Q Chassis Dimensions Bottom 12 700 322 58 1 01 25 7 1 02 25 8 8 650 219 7 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 56: ...it Components Note The chassis shown in Figure A 3 is representative of the NI PXI 1042 NI PXIe 1062Q product line 1 Front Rack Mount Kit 2 NI Chassis 3 Optional Rear Rack Mount Kit 1 2 3 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 57: ... slot Table B 7 shows the XP4 Connector Pinout for the System Timing slot Table B 8 shows the P1 Connector Pinout for the Peripheral slots Table B 9 shows the P2 Connector Pinout for the Peripheral slots Table B 10 shows the P1 Connector Pinout for the Hybrid Peripheral slots Table B 11 shows the XP3 Connector Pinout for the Hybrid Peripheral slots Table B 12 shows the XP4 Connector Pinout for the...

Страница 58: ...n3 GND 3PERp3 3PERn3 GND 3PERp2 3PERn2 GND 3 4PETp0 4PETn0 GND 4PERp0 4PERn0 GND 4PETp1 4PETn1 GND 4 4PETp2 4PETn2 GND 4PERp2 4PERn2 GND 4PERp1 4PERn1 GND 5 4PETp3 4PETn3 GND 4PERp3 4PERn3 GND RSV RSV GND 6 RSV RSV GND RSV RSV GND RSV RSV GND 7 RSV RSV GND RSV RSV GND RSV RSV GND 8 RSV RSV GND RSV RSV GND RSV RSV GND 9 RSV RSV GND RSV RSV GND RSV RSV GND 10 RSV RSV GND RSV RSV GND RSV RSV GND Manu...

Страница 59: ...Tp1 2PETn1 GND 2PERp1 2PERn1 GND 2PERp0 2PERn0 GND 9 2PETp2 2PETn2 GND 2PERp2 2PERn2 GND 2PETp3 2PETn3 GND 10 3PETp0 3PETn0 GND 3PERp0 3PERn0 GND 2PERp3 2PERn3 GND Table B 4 XP4 Connector Pinout for the System Controller Slot Pin Z A B C D E F 1 GND GA4 GA3 GA2 GA1 GA0 GND 2 GND 5Vaux GND SYSEN WAKE ALERT GND 3 GND RSV RSV RSV RSV RSV GND 4 GND RSV RSV RSV RSV RSV GND 5 GND PXI_TRIG3 PXI_TRIG4 PXI...

Страница 60: ...NC NC GND 10 NC NC GND NC NC GND NC NC GND Table B 6 XP3 Connector Pinout for the System Timing Slot Pin A B ab C D cd E F ef 1 PXIe_CLK100 PXIe_CLK100 GND PXIe_SYNC100 PXIe_SYNC100 GND PXIe_DSTARC PXIe_DSTARC GND 2 PRSNT PWREN GND PXIe_DSTARB PXIe_DSTARB GND PXIe_DSTARA PXIe_DSTARA GND 3 SMBDAT SMBCLK GND RSV RSV GND RSV RSV GND 4 MPWRGD PERST GND RSV RSV GND 1RefClk 1RefClk GND 5 1PETp0 1PETn0 G...

Страница 61: ...ND GND GND 4 GND GND GND 3 3V 3 3V 3 3V GND 5 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 6 GND PXI_TRIG2 GND ATNLED PXI_CLK10_IN PXI_CLK10 GND 7 GND PXI_TRIG1 PXI_TRIG0 ATNSW GND PXI_TRIG7 GND 8 GND PXIe_SYNC_CTRL GND RSV PXI_LBL6 PXI_LBR6 GND Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 62: ... GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST GND GNT GND 4 GND IPMB_PWR HEALTHY V I O...

Страница 63: ...PXI_LBL6 PXI_LBR6 GND 14 GND RSV RSV RSV GND RSV GND 13 GND RSV GND V I O RSV RSV GND 12 GND RSV RSV RSV GND RSV GND 11 GND RSV GND V I O RSV RSV GND 10 GND RSV RSV RSV GND RSV GND 9 GND RSV GND V I O RSV RSV GND 8 GND RSV RSV RSV GND RSV GND 7 GND RSV GND V I O RSV RSV GND 6 GND RSV RSV RSV GND RSV GND 5 GND RSV GND V I O RSV RSV GND 4 GND V I O 64EN RSV GND RSV GND 3 GND PXI_LBR7 GND PXI_LBR8 PX...

Страница 64: ...D PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST GND GNT GND 4 GND IPMB_PWR HEALTHY V I O IN...

Страница 65: ...ND 1PETp4 1PETn4 GND 8 1PETp5 1PETn5 GND 1PERp5 1PERn5 GND 1PERp4 1PERn4 GND 9 1PETp6 1PETn6 GND 1PERp6 1PERn6 GND 1PETp7 1PETn7 GND 10 RSV RSV GND RSV RSV GND 1PERp7 1PERn7 GND Table B 12 XP4 Connector Pinout for the Hybrid Slot Pin Z A B C D E F 1 GND GA4 GA3 GA2 GA1 GA0 GND 2 GND 5Vaux GND SYSEN WAKE ALERT GND 3 GND 12V 12V GND GND GND GND 4 GND GND GND 3 3V 3 3V 3 3V GND 5 GND PXI_TRIG3 PXI_TR...

Страница 66: ...titles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to eLearning training modules at ni com elearning All customers automatically receive a one year membership in the Standard Service Program SSP with the purchase of most software products and bundles including NI Developer Suite NI also offers flexible exten...

Страница 67: ...his system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification Calibration Certificate If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration You also can visit the Worldwide Offices section of ni com niglobal to access the branch...

Страница 68: ...ymbols Degrees Equal or greater than Equal or less than Percent A A Amperes AC Alternating current ANSI American National Standards Institute Auto Automatic fan speed control AWG American Wire Gauge Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Страница 69: ...dard mechanical components and high performance connector technologies to provide an optimized system intended for rugged applications It is electrically compatible with the PCI Specification which enables low cost PCI components to be utilized in a mechanical form factor suited for rugged environments CSA Canadian Standards Association D daisy chain A method of propagating signals along a bus in ...

Страница 70: ... equal to 9 8 m s2 GPIB General Purpose Interface Bus IEEE 488 gRMS A measure of random vibration The root mean square of acceleration levels in a random vibration test profile H hr Hours Hz Hertz cycles per second I IEC International Electrotechnical Commission an organization that sets international electrical and electronics standards IEEE Institute of Electrical and Electronics Engineers IMP M...

Страница 71: ... a specified change in input AC voltage step change from 90 to 132 VAC or 180 to 264 VAC load regulation The maximum steady state percentage that a DC voltage output will change as a result of a step change from no load to full load output current M m Meters MHz Megahertz One million Hertz one Hertz equals one cycle per second mi Miles ms Milliseconds MTBF Mean time between failure MTTR Mean time ...

Страница 72: ...ut the chassis is still connected to AC power mains NI P power supply shuttle PXI PXI_CLK10 R RH RMS S s skew slot blocker standby System controller A module configured for installation in Slot 1of a PXI chassis This device is unique in the PXI system in that it performs the system controller functions including clock sourcing and arbitration for data transfers across the backplane Installing such...

Страница 73: ...nectors on the rear of the chassis can be used to synchronize multiple chassis to one reference clock The PXI backplane specification defines implementation guidelines for PXI_CLK10 System Timing slot This slot is located at slot 4 and has dedicated trigger lines to other slots T TTL Transistor transistor logic U UL Underwriter s Laboratories V V Volts VAC Volts alternating current Vpp Peak to pea...

Страница 74: ...2 2 figure 2 3 CLK10 rear connectors 2 13 CompactPCI interoperability with NI PXIe 1062Q backplane 1 6 configuration in MAX figure 2 14 configuration See installation configuration and operation connector pinouts See pinouts conventions used in the manual vii cooling air cooling of an NI PXIe 1062Q chassis 2 2 filler panel installation 2 5 setting fan speed 2 5 slot blocker installation 2 5 D DB 9...

Страница 75: ... system controller installed in a NI PXIe 1062Q chassis figure 2 8 PXI 1 configuration in MAX 2 15 rack mounting 2 5 remote voltage monitoring and inhibiting interface 2 11 setting fan speed 2 5 site considerations 2 2 slot blocker installation 2 5 testing power up 2 6 unpacking the NI PXIe 1062Q 1 1 installing a PXI Express system controller figure 2 7 instrument drivers NI resources C 1 interope...

Страница 76: ...connector table B 6 P2 connector table B 7 pinouts B 1 DB 9 connector table 2 11 power cables table 1 2 power inhibit switch LED indicator 2 10 power supply connecting to 2 6 remote voltage monitoring and inhibiting interface 2 11 replacing 3 3 configuration 3 4 connecting safety ground 3 4 connecting to power source 3 4 installation 3 4 removal 3 3 voltages at voltage monitoring connector DB 9 ta...

Страница 77: ...ent A 4 storage environment A 5 external clock source A 9 mechanical A 10 PXI differential star triggers PXIe DSTARA PXIe DSTARB PXIe DSTARC A 10 PXI star trigger A 9 PXIe_SYNC_CTRL A 9 rack mount kit dimensions figure A 14 safety A 6 shock and vibration A 5 system reference clocks A 8 static discharge damage caution 3 1 support technical C 1 system controller slot description 1 7 pinouts XP1 conn...

Страница 78: ...oltage monitoring connector See DB 9 connector voltages at voltage monitoring connector DB 9 table 2 12 W Web resources C 1 Manual Sales 44 0 1273 570 220 Website www amplicon com Email sales amplicon com IT and Instrumentation for industry Amplicon com ...

Отзывы: