Chapter 2
Installation and Configuration
Inhibit Mode Switch
On the rear panel of the chassis there is an Inhibit Mode switch. Refer to
Figure 1-2,
Rear View of the NI PXIe-1062Q Chassis
Inhibit Mode switch is recessed to prevent it from accidentally being
switched.
The Inhibit Mode switch should be in the
Default
position when normal
power inhibit switch functionality is desired. If the user needs to power on
a chassis without a system controller installed the switch should be in the
Manual
position.
When the Inhibit Mode switch is set to the
Manual
position, the power
supplies are enabled, and you can use the Inhibit signal (active low) on
pin 5 of the Remote Inhibit and Voltage Monitoring connector to power off
the chassis. To remotely power off the chassis, connect the Inhibit pin
(pin 5) to a Logic Ground pin (pin 1 or 9). As long as this connection exists,
the chassis will remain off (standby); when you remove this connection, the
chassis turns on.
Note
For the Remote Inhibit signal to control the On/Off (standby) state of the chassis, the
Inhibit Mode switch must be in the
Manual
position.
PXI_CLK10 Rear Connectors
There are two BNC connectors on the rear of the NI PXIe-1062Q chassis
for PXI_CLK10. The connectors are labeled IN and OUT. You can use
them for supplying the backplane with PXI_CLK10 or routing the
backplane’s PXI_CLK10 to another chassis. Refer to the
, for details about these signals.