Amphenol THE MODAL SHOP K2060E030 Скачать руководство пользователя страница 2

 
 

 

K2060E030 Shaker Kit Selection and Quick Start 

GuideGuide 

DS-0150 revB

 

www.modalshop.com   |   513-351-9919   |   [email protected] 

 

 

Connecting the K2060E030 shaker kit 

1.

 

Connect shaker cable to amplifier (see below table) 

Shaker Cable Wire Color 

Function 

2050E05 

2100E21-400 

Red 

Armature 

OUT / OUT 

OUT /  

Orange & Blue 

Armature 

RET / RET 

RET / SHAKER - 

White/Black 

Interlock 

+ / + 

+ / Int 

White 

Interlock 

INT / INT 

INT / Interlock - 

Black 

Ground 

GND / GND 

GND / Earth Ground 

 

2.

 

Connect the shaker cable to shaker. 

3.

 

Power amplifier with included power cable 

4.

 

Connect input signal via the BNC connector labeled “

Signal Input

 on the back of the 2100E21-400 or to 

the BNC connector labeled “AC”

 on the back of the 2050E05 amplifier. 

5.

 

Turn on master power switch and position gain knob to desired setting.  

Note:  

Master power switch is 

located on the back of the 2100E21-400 amplifier and on the front of the 2050E05 amplifier. 

2100E21-400 User Tips 

 

As a safety measure, if the gain knob is not in the “mute”

 position when power is turned on, it will need to 

be turned 

to “mute” before amplifier can be used.

   

 

Output clipping error:  Anytime the output waveform is clipped due to too much gain or the input 

amplitude being too high, the LCD screen will flash the “output clipping” message until the clipping stops. 

This helps avoid unwanted output distortion. During clipping, all menus and buttons remain functional. 

 

Output interlock: Anytime an error or a fault condition occurs while the amplifier is on, the amplifier will 
automatically mute and a message will be displayed on the LCD.  

Consult the “

Troubleshooting Guide

” i

the manual to fix any problem that caused the error, and press F1 to clear the error message. If the gain 

knob is not turned to “mute,” it will have to be turned to “mute” first before the amplifier can be turned 

back on. 

 

2050E05 User Tips 

 

Trip indicator flashing:  

The “TRIP” indicator flashes if the amplifier has been turned on with the gain out 

of the reset position or if the external (fault open) interlock is open. The amplifier output is inhibited 
during this interlock condition. The indicator also flashes during a heat sink over-temperature condition. 
The amplifier output will be compressed if the overheat condition persists but will automatically restore 
itself after the heat sink temperature drops. 

 

The output peak voltage bar graph indicates the peak voltage applied to the shaker and will indicate 
voltage clipping limits and output signal level. It can also be useful in detecting output open circuit 
problems. The output RMS current level graph indicates the amount of current being delivered to the 
shaker and can be used to prevent overdriving and subsequent damage to connected loads

 

Videos

 and 

FAQ guides

 are available online.  Feel free to contact The Modal Shop for support at 

[email protected]

 or +1 513-351-9919. 

 