RESMLAC 8MG CAPS POE - UM
rev. 1
Page 7/16
www.amphenol-socapex.com
Tel: +33(0)4.50.89.28.00
Section 4
Wiring
Overview
These switches provide connections to Ethernet devices in harsh environment. Typically,
a port is used to connect to another Ethernet switch that is connected to the main Ethernet
backbone. The other Ethernet ports are then connected to Ethernet devices such as
communication systems, Ethernet I/O, or industrial computers. Electrical isolation is
provided on the Ethernet ports for increased reliability.
Please follow normal Ethernet wiring practices when installing these switches.
Power wiring
The switches should be powered using mating plugs and backshells compliant with MIL-
DTL-38999 series III. We suggest using hereunder accessories. Another backshell can be
used but it must ensure a correct sealing protection.
Power plug
part number
Amphenol designation: TV06 RW 13 04S
This plug is size 13. It is coming with 4 contacts size 16 (designed for
13A nominal current).
Power plug
wiring
Contact
Signal
Suggested Harness
Color Table
A
24 V (+)
red
B
24 V (-)
black
C
Not connected
None
D
Not connected
None
Ethernet
wiring
These switches provide connections to Ethernet devices on the battlefield. Typically, a
port is used to connect to another Ethernet switch or hub that is connected to the main
Ethernet backbone. The other Ethernet ports are then connected to Ethernet devices such
as communication systems, Ethernet I/O, or industrial computers. Electrical isolation is
provided on the Ethernet ports for increased reliability.
Please follow normal Ethernet wiring practices when installing these switches.
The switches should be connected using mating plugs and backshells compliant with
MIL-DTL-38999 series III. We suggest using hereunder accessories. Another backshell
can be used but it must ensure a correct sealing protection.
Ethernet plug
part number
Amphenol designation: TV06RW0909P .
This plug is size 9. It is coming with 9 contacts size 23.
Ethernet plug
wiring
Contacts
TV 0909
Signal
type
Description
Contacts
RJ45
1
P3+
10/100/1000 BaseT Pair 3 Positive
7
2
P1-
10/100/1000 BaseT Pair 1 Negative
6
3
P1+
10/100/1000 BaseT Pair 1 Positive
3
4
P2-
10/100/1000 BaseT Pair 2 Negative
5
5
P2+
10/100/1000 BaseT Pair 2 Positive
4
6
P0-
10/100/1000 BaseT Pair 0 Negative
2
7
P0+
10/100/1000 BaseT Pair 0 Positive
1
8
P3-
10/100/1000 BaseT Pair 3 Negative
8