Amphenol ePower-Lite Mini Скачать руководство пользователя страница 8

Receptacle

HVIL Wire Size

Recommended Min. Pullout force (N)

2 ports

22 AWG

40

20 AWG

60

Recommended HVIL Wire Specification

Recommended Crimping tool as below (P/N: FX3-0095-000):

Step 3:

 

Insert the HVIL contacts into the receptacle shell assembly, the claws face to the sides

Содержание ePower-Lite Mini

Страница 1: ...CABLE ASSEMBLY WORK INSTRUCTION ePower Lite Mini AI 11...

Страница 2: ...errule 2 Recommended wire specification Part 1 Package Contents Part 2 Assembly Wire Size Wire OD mm Recommended Min Pullout force N 4 0mm2 5 8 0 2 325 Item 2 Ports Include all cable sizes L 21 5 0 5...

Страница 3: ...ble the outer ferrule and crimping to right crimp height 7 5 0 1 mm cutting and the jacket Step 4 Stripping the jacket and cut off the exposed shielding wire of cable crimping the terminal by right cr...

Страница 4: ...collar snapped into the shoulder of the hole Step 6 Install the cable grommet Step 7 Install the cable cover Notes Need to do Insulation Resistance and DWV test after cable assembly Insulation Resist...

Страница 5: ...CABLE ASSEMBLY WORK INSTRUCTION ePower lite Mini Series Receptacle Connector...

Страница 6: ...ket Contact Part 1 Package Contents Part 2 Assembly Steps for Power Pin Wire Size Recommended Min Pullout force N 4 0mm2 325 Step 1 4mm2 wire cutting and stripping jacket dimensions Step 2 Insert cond...

Страница 7: ...collar snapped into the shoulder of the hole Recommended manual crimping tool as below P N FX3 0094 000 Part 3 Assembly Steps for HVIL pin Step 1 Wire cutting and stripping the jacket Step 2 Insert c...

Страница 8: ...ded Min Pullout force N 2 ports 22 AWG 40 20 AWG 60 Recommended HVIL Wire Specification Recommended Crimping tool as below P N FX3 0095 000 Step 3 Insert the HVIL contacts into the receptacle shell as...