Amphenol BLD7754-PTE Скачать руководство пользователя страница 1

PROTIMETER

Protimeter Hygromaster2

Instruction Manual

Amphenol

Advanced Sensors

INS7750 Rev. A

October 2015

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Содержание BLD7754-PTE

Страница 1: ...timeter Hygromaster2 Instruction Manual Amphenol Advanced Sensors INS7750 Rev A October 2015 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquip...

Страница 2: ......

Страница 3: ...Protimeter Hygromaster2 Instruction Manual INS7750 Rev A October 2015...

Страница 4: ...no content intended for this page...

Страница 5: ...to measurement or settings screens based on Selection 2 Left button Press once to navigate to one screen back 3 Right button a Press once to freeze the readings in measurement screens b Press and hold...

Страница 6: ...ometrics Selection and Use 6 4 3 Condensator 7 4 4 Logging Selection and Use 9 4 5 Settings Selection and Use 10 5 Diagnostic Procedure Guidelines 14 6 Calibration Checking 16 7 Care and Maintenance 1...

Страница 7: ...Contents v INS7750 Rev A...

Страница 8: ...rement range of the IR temperature mode and the accuracy of the measurement is not guaranteed outside the range Calibration of unit The accuracy specifications of the product are valid for one year af...

Страница 9: ...r the better 3 Product Components and Accessories The Hygromaster2 instrument measures air temperature relative humidity and surface temperature To measure all the above mentioned parameters Hygromast...

Страница 10: ...POL8750 Short Quikstick POL8751 and 30cm humidity probes BLD8755 measure relative humidity RH and ambient air temperature in rooms or materials They can be connected to the Hygromaster2 instrument ei...

Страница 11: ...ly after 2 minutes if no activity is observed unless the default settings are changed see Section 4 7c Auto Off on page 17 for instructions To switch the instrument OFF immediately press and hold for...

Страница 12: ...d Relative humidity and temperature measurements are made with the Hygrostick Quikstick or Short Quikstick probe and the Hygromaster2 Instrument uses these values to calculate a range of psychometric...

Страница 13: ...s per Pound Grams per Kilogram Navigate to SELECT MODE PSYCHROMETRICS GRAMS PER KILOGRAM GRAINS PER POUND and press to get the Mixing Ratio reading 4 2c Enthalpy Navigate to SELECT MODE PSYCHROMETRICS...

Страница 14: ...t B and making contact with the surface to be assessed In addition to the Surface Temperature probe connect a Humidity probe into socket A for the Hygromaster2 to show the Condensation status TDIFF is...

Страница 15: ...Selection and Use cont Figure 5 LASER Pointer Table 3 TDIFF Readings T DIFF DEGC Condensation Status Background Colour 0 Condensation Red Blinking 0 but 3 Risk of Condensation Yellow Blinking 3 No Con...

Страница 16: ...is enabled either by setting logging parameters through the Keypad or through a PC using Logging Software see Section 4 7g Set Logging Parameters Optional PC Logging Software Required on page 19 After...

Страница 17: ...AGE and press to open the language options Use to navigate among the options available and press to save the desired language 4 5b Set Units Hygromaster2 has the option to select between METRIC and NO...

Страница 18: ...n use to increment decrement the value in that box After entering the required date press to save date entered and go to Time setting screen Use to navigate to the required field Then use to increment...

Страница 19: ...N OFF will be indicated Navigate to SELECT MODE SETTINGS BUZZER and press to switch the Buzzer on off Use to navigate between the on and off options and press to save the desired configuration 4 5h Ca...

Страница 20: ...gging via the optional PC software 4 5j Clear Logging Data Hygromaster2 has an option to erase the logging data in Flash Navigate to SELECT MODE SETTINGS LOGGING CLEAR DATA and press Then it will disp...

Страница 21: ...t condensation occurs When the Protimeter Hygromaster2 Condensator Mode is selected to measure TDIFF the proximity of a surface to the dew point the instrument identifies either a NO CONDENSATION Cond...

Страница 22: ...utside this range Item 2 Two hygroscopic salts chlorides and nitrates may build up on the surface of walls where rising dampness or wicking occurs As groundwater moves through the wall and migrates to...

Страница 23: ...d its accessories in the factory carry case Store the case in a stable dust free environment and keep it out of direct sunlight If the instrument is to be stored for more than four weeks or if the low...

Страница 24: ...to SELECT MODE ABOUT to view the Hygromaster2 information The following information will be provided Firmware version Date of build Device Model and Serial number Battery status Calibration date stat...

Страница 25: ...Hygrostick Data Nominal Relative Humidity Range 30 to 40 RH Accuracy 3 RH at 68 F 20 C Range 41 to 98 RH Accuracy 2 RH at 68 F 20 C Temperature Range 14 F to 122 F 10 C to 50 C Accuracy 0 6 F 0 3 C S...

Страница 26: ...uction Manual 9 2b Surface Temperature Thermistor Based Remote Non Integrated Probe Range 4 F to 176 F 20 C to 80 C Accuracy 2 7 F 1 5 C IR Based With 12 1 D S Ratio With Laser Pointer Range 14 F to 1...

Страница 27: ...8 cm 9 3c Gross Weight Instrument only 6 42 oz 182 g 9 3d Buzzer Audible buzzer for Key tone 9 4 Regulatory Compliance CE RoHS ETL 9 5 User Interface 9 5a Keypad Plastic silicone keypad for easy navi...

Страница 28: ...application settings 9 5e PC Interface USB interface mini B type USB port on instrument PC Interface features Firmware Upgrade in field User specific instrument setup Data Logging setup Stored data r...

Страница 29: ......

Страница 30: ...Customer Support Centers Amphenol Advanced Sensors INS7750 Rev A December 2015 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Отзывы: