PAGE 3
3. FRONT PANEL ZONE SWITCHES - ZONE 7 TO 12
Switching for zone 7 - 12 for ZS5121 only. Refer to Application example for grouping.
4. ALL CALL SWITCH
All zones will be activated by pressing this switch, regardless of any inactive zone.
5. DC SUPPLY INPUT PORT
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is
recommeded that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as
a DC supply source to your installation.
6. EMERGENCY OVERRIDE TERMINAL
External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger
the built in relay when pressed. This shall then provide a dry contact in which would enable the installer to
apply several functions such as providing 24V DC output for volume controller overriding purpose, trigger
external device or link to BAS system, etc.
7. REMOTE SELECT PORT - Z1 TO 6
8. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 1 TO 6)
Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the
respective unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes
with single amplifier output connection.
Please observe palarity when terminating the amplifier / speaker zones and ensure that each zone is over
overloaded ( less than 400 W rms )
9. REMOTE SELECT PORT - Z7 TO 12
Similiar function as Part7 but only available for ZS5121
10. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 7 TO 12)
Similiar to Part 7 but only available for model ZS 5121
PARTS IDENTIFICATION
ampereselectronics.com
This is to connect to remote paging mic ( PM series ) or Data Decoder ( TD Series ) for remote zone trigger-
ing. Upon triggering the zone via this port, it shall override the locally selected zones. External triggering
switches or other mades of paging microphone can utilise this facility provided -ve triggering method is used.