Amperes ZS5121 Скачать руководство пользователя страница 3

PAGE 3

3.   FRONT PANEL ZONE SWITCHES - ZONE 7 TO 12

Switching for zone 7 - 12 for ZS5121 only. Refer to Application example for grouping.

4. ALL CALL SWITCH

All zones will be activated by pressing this switch, regardless of any inactive zone.

5.   DC SUPPLY INPUT PORT

24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is 
recommeded that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as 
a DC supply source to your installation.

6.   EMERGENCY OVERRIDE TERMINAL

External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger 
the built in relay when pressed. This shall then provide a dry contact in which would enable the installer to 
apply several functions such as providing 24V DC output for volume controller overriding purpose, trigger 
external device or link to BAS system, etc.

7.  REMOTE SELECT PORT - Z1 TO 6

8. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 1 TO 6)

Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the 
respective unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes 
with single amplifier output connection.

Please observe palarity when terminating the amplifier / speaker zones and ensure that each zone is over 
overloaded ( less than 400 W rms )

9.   REMOTE SELECT PORT -  Z7 TO 12

Similiar function as Part7 but only available for ZS5121

10. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 7 TO 12)

Similiar to Part 7 but only available for model ZS 5121

PARTS IDENTIFICATION

ampereselectronics.com

This is to connect to remote paging mic ( PM series ) or Data Decoder ( TD Series ) for remote zone trigger-
ing. Upon triggering the zone via this port, it shall override the locally selected zones. External triggering 
switches or other mades of paging microphone can utilise this facility provided -ve triggering method is used.

Содержание ZS5121

Страница 1: ...ZS ZS 5601 6 Channel Speaker Zone Selector 5121 12 Channel Speaker Zone Selector amperes the emerging preference www ampereselectronics com INSTRUCTION MANUAL...

Страница 2: ...e selection This is active if Amperes PM 1060 paging is used or any other paging microphone console with Priority output signal 2 FRONT PANEL ZONE SWITCHES ZONE 1 TO 6 Switching for zone 1 to 6 They c...

Страница 3: ...ternal device or link to BAS system etc 7 REMOTE SELECT PORT Z1 TO 6 8 AMPLIFIER ZONE OUTPUT CONNECTORS ZONE 1 TO 6 Outputs from amplifiers are connected to these terminals and speaker zoning is confi...

Страница 4: ...can be made from remote area but the front panel switches has to be at OFF position Note The sample connections shown are using a single unit of either ZS5121 or ZS5601 in a small scale installation...

Страница 5: ...l Call and PR from remote mic shall not be required PIN 8 COM PIN 7 24V PIN 6 Z6 PIN 5 Z5 PIN 4 Z4 PIN 3 Z3 PIN 2 Z2 PIN 1 Z1 PIN 8 COM PIN 7 24V PIN 6 Z12 PIN 5 Z11 PIN 4 Z10 PIN 3 Z9 PIN 2 Z8 PIN 1...

Страница 6: ...e limits as indicated Polarity must also be observed when connecting this port to trigger volume controller overriding relay etc ampereselectronics com PIN 8 COM PIN 7 24V PIN 6 Z6 PIN 5 Z5 PIN 4 Z4 P...

Страница 7: ...nnectors with screw terminals CABLE SIZE Up to 2 5 mm sq DIMENSIONS 482 W X 44 H X 180 D mm WEIGHT ZS 5601 2 1 kg ZS 5121 2 8 kg COLOUR Black Powder epoxy coating NOTE Amperes Electronics Sdn Bhd has...

Страница 8: ...only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufactur...

Отзывы: