background image

Front View:

Parts Identifications

Rear View:

1

2

4

5

8 9 10

10.  OUTPUT MODE

1.  POWER LED

It is to indicate the presence of 24V DC supply to the unit.

5.  REMOTE ACTIVATION PORT

Triggering of the siren / tone / chime can be done remotely. Auto dual mode triggering is available for all ports; 

momentarily or latched.

9.  GAIN CONTROL

The output is line level, 0dB. Adjust the volume via this knob.

The user shall have option to have balanced or unbalanced output by using this switch.

2.  SIREN SWITCHES

The switches activate siren in constant or wavy mode. Press once to active and again to switch Off. Siren broadcast 

shall has priority over chime or tone activation.

3.  TONE / CHIME GENERATION

The activation is via momentary switches. While any of the tone is in active mode, pressing the siren shall bypass it. 

Tones available are 4 tone up / down, 2 tone, westminster, bell rings and ding dong. 

4.  POWER SUPPLY

The unit operates using 24V DC supply with rating of 0.3A.

Warning :

Do not connect the unit directly to back up batteries, as higher voltage in charging mode shall damage the unit.

We recommend Amperes PS9400 power supply unit or any other regulated 24V DC adaptor. 

PAGE 2

CM1400 | CHIME AND SIREN TONE GENERATOR

11.  OUTPUT JACK

Output is via 1/4" stereo jack.

PHONE JACK

TIP : +VE / HOT SIGNAL

RING : -VE / COLD

SLEEVE : GROUND / SCREEN

CM 1400

amperes

SIREN / CHIME GENERATOR

POWER

SIREN -

SIREN ~

4T UP

4T DOWN

2 TONE

WESTMINSTER

BELL

DOOR BELL

-

+

DC 24V

WEST.

2 TONE

BELL

SIREN ~

SIREN -

DING D.

4 T. UP

4 T.DOWN

MIN

MAX

OUTPUT

SELECT SWITCH

UNBALANCED

BALANCED

1.0 V / 10K Ω

OUTPUT

NO

A B

RS485

RELAY

CONT

GND

CM 

1400

CHIME/SIREN GENERATOR

SIREN    ~ LATCHED CONTACT.

CHIMES ~ MOMENTARY CONT.

        REPEAT IF LATCHED.

REMOTE TRIGGERING

amperes electronics

Another Quality Product From

MADE IN MALAYSIA

INPUT GAIN

     TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSE THIS

    EQUIPMENT TO RAIN OR MOISTURE.

WARNING !

11

3

7.  RELAY CONTACT

Triggering the front panel mic switch message or siren shall activate an internal relay. This ports provide a dry contact 

which can be used to connect E/M overriding signal or to activate ALL CALL at speaker zone selector.

8.  RS485

External controls or interface devices shall be able to communicate with the unit.

7

6.  GND 

Ground and external trigger will form a pair of circuit for remote activation.

6

Отзывы: