Maintenance
Ampco Pumps Company
Ampco Pumps Company ZP3 Manual M-004 Rev A 10.15
Page 22
Pump Clearances
The performance of a ZP3 is based on the tight clearances between the pump body and the
rotors. These clearances are critical to ensure the pump performs up to the system
requirements. The clearance between the rotor and the back face of the body is referred to as
the backface clearance. Other clearances are shown in Figure 39 and should be in
accordance to Table 4. Use shims and a depth micrometer to measure the clearances.
Figure 39: Critical Pump Clearances
Table 4: Critical Pump Clearance Dimensions (Standard Rotors)
A (Backface Clearance)
B (Rotor to Body Clearance)
C (Front Face Clearance)
Note: For non-standard
rotors contact Ampco
A
(Backface Clearance)
B
(Rotor to Body Clearance)
ZP3 Model
Inch
mm
Inch
mm
Inch mm
6, 15, 18
.002 .05 .002 .05 .005 .13
30, 34
.002 .05 .002 .05 .005 .13
45, 60, 64,
.004 .10 .005 .13 .008 .20
180, 220, 224
.005 .13 .006 .15 .008 .20
210, 320
.005 .13 .010 .25 .011 .28
C
(Front Face Clearance)
130, 134
.004 .10 .005 .13 .008 .20
Measuring A
Cutaway
Measuring B
Measuring C
Depth
Mic.