28
3. The o-rings on the stationary
seal must be lubricated well or it
will be very difficult to push the
stationary seal into the its’ bore.
Line up the flats on the stationary
seal with the rectangular hole in the
hub of the casing. See figure 30.
4. Install the stationary seal push-
ing the stationary seal into the cas-
ing bore.
5. Make sure the stationary seal
seats against the back face of the
bore.
Figure 30
Figure 32
Figure 31
LF & LM SERIES PUMPS