6.2.2  Key to exploded drawing 

Part Number 

Spares Kit 

Description 

CIRCI47-1 

 

Front bearing retaining circlip 

WSHR47-4 

AM SP3054 

Front bearing washer 

BRNG-6204-2RS 

Front bearing 

BRNG-6202-2RSR 

Rear bearing 

ORG1585IX353 

Main body O ring 

METL00019 

 

Outer bearing spacer 

METL00020 

 

Inner bearing spacer 

METL00006-1 

 

Alternator shaft 

ASMB00013 

 

Slip ring assembly 

BRNG-6202-2RSR 

AM SP6026 

Pivot top bearing 

NMETL00002 

Pivot lower plain bearing 

ORG59IX533 

Lower plain bearing O ring 

SPRG00002 

Spiral retaining ring 

SEAL-VA-040 

AM SP1030 

Pivot shaft V seal 

METL00021 

 

Pivot shaft 

CBLSR-PG11 

 

Cable gland 

ASMB00002 

 

Brush holder assembly 

BRSH00001 

AM SP3035 

Brush set (3 off) 

SCRM4x8-06SS 

 

M4x8 machine screws 

CSTM00005 

 

Electrical box lid 

NMETL00006 

 

Insulating washer 

SCRM4x12-12SS 

 

M4x12 self tapping screws 

METL00025 

 

Tail fin 

SCRM8x20-01SS 

 

M8x20 bolts 

NTSM8-01 

 

M8 nuts 

CSTM00003 

 

Main body 

ASMB00014 

 

Rotor assembly 

ASMB00017 

 

Stator assembly 

CSTM00002 

 

Front cover 

SCRM5x50-01SS 

 

M5x50 bolts 

ASMB00005 

AM SP3012 

Hub assembly 

NMETL00008 

AM SP3014 

Blade set (3 off) 

METL00014 

AM SP3051 

Hub cap screw 

 

AM SP3037 

Rectifier assembly & heat-sink 

 

Содержание 300

Страница 1: ...Date 02 Feb 2011 Ampair 300 Mk1 Pacific Wind Turbine Manual CD 2300 Issue 1 2 Page 1 of 34 1 Ampair April 2007 Ampair 300 Wind Turbine Operation Maintenance Manual ...

Страница 2: ...RMANCE 25 5 1 Starting and stopping 25 5 2 Performance 26 6 INSPECTION MAINTENANCE 27 6 1 Major disassembly 27 6 2 Drawings and component list 31 6 3 Recommended spares 33 7 WARRANTY 33 8 SERVICING REPAIRS DISPOSAL 33 Disclaimer The information in this manual is believed to be correct and reliable However Ampair assumes no responsibility for inaccuracies and omissions The user of this information ...

Страница 3: ... of Boost Energy Systems Ltd manufacturers of distributed energy systems for fifty years Ampair and PowerFurl are trademarks of Ampair and Boost Energy Systems Ltd The label with the model type and nominal voltage is on the electrical box cover where the name Ampair is shortened to AMPAIR The serial number of the wind turbine is stamped on the lower left side of the main body casting on the outsid...

Страница 4: ...are a variety of sources of potential hazards which can result in death or serious injury These dangers exist during installation operation or inspection and maintenance 2 2 1 Mechanical dangers The main dangers are the spinning rotor and the tail The rotor blades are very sharp and can cause very serious injuries even at low speeds WARNING Never touch the rotating rotor the blades or hub Never tr...

Страница 5: ...ly high If you do so there is a serious risk that you will set the battery and cabling on fire as well as releasing flammable and potentially explosive gases hydrogen from the battery and you will probably destroy the battery WARNING Never short circuit the battery Install fuses immediately adjacent to the wind turbine side of the battery but not within the battery compartment as the spark from a ...

Страница 6: ...work team thoroughly including the actions in the event of an accident and or injury WARNING Whenever possible work on the ground or deck not at a height Use safety harnesses safety helmets and safety slings etc Use man rated lifting equipment and access systems Work in daylight on windless days and in calm seas Keep the work area clear plan your work have your entire equipment ready and brief the...

Страница 7: ...ting systems The diagram below shows the external dimensions in millimetres mm 3 2 Technical data Nominal power 300 Watts Rated wind speed for nominal power 12 6 metres per second 25 knots or 29 miles per hour Cut in wind speed 3 metres per second 6 knots or 6 9 miles per hour Thermal cut out None Survival wind speed Storm proof Rotor diameter 1 2 metre Number of blades 3 Blade material Glass rein...

Страница 8: ...se The top bearing is captive in the body the lower bearing is located in the body by a stainless steel spiral retaining ring The pivot section contains an O ring around the lower bearing to body junction and a V seal where the pivot shaft passes through the lower bearing The pivot axis passes through the centre of gravity of the assembled machine This is necessary to ensure alignment into the win...

Страница 9: ...s possible so as to minimise losses due to the resistance of the wiring system For this reason the rectifier of the Pacific 300 is not fitted inside the generator but is instead supplied as a separate unit for fitting adjacent to the regulator and or battery The rectifier is a three way bridge rectifier mounted on a heat sink 3 3 3 Other system components The basic wind turbine package only consis...

Страница 10: ...Ampair 300 Mk1 Pacific Wind Turbine Manual CD 2300 Issue 1 2 Page 10 of 34 10 Ampair April 2007 4 2 Wind turbine packing list The Pacific 300 Wind Turbine is packaged in recyclable cardboard cartons The cartons contain ...

Страница 11: ...0mm Four 6 5mm holes each end C 1 pcs Pole C 970mm 25mm OD strut pole D 2 pcs Stay wires Terminated by thimbles and D ring nuts E 1 pcs Bag 1 Containing yoke two angle feet and backstay clamp shell F 1 pcs Bag 2 Containing one anodised aluminium alloy joiner tubes G 1 pcs Kit 1 Strut yoke feet fixings 1 pcs M6 x 40mm screw 2 pcs M6 x 35 hex screw 3 pcs M6 shakeproof washers 3 pcs M6 Nyloc nuts 1 p...

Страница 12: ... Ampair 300 Basic Regulator comes in two versions the 12 volt or the 24 volt version It is not possible to convert these from one to the other The carton contains A 1 pcs Regulator 12 volt or 24 volt version B 1 pcs Operation manual 4 3 7 Pacific 300 advanced regulator The Ampair 300 Advanced Regulator comes in only one version which can be configured for either 12 volt or 24 volt use by Ampair au...

Страница 13: ...These conditions are shown diagrammatically below WARNING Before a wind turbine is installed in an excessively windy location the operators must satisfy themselves that the site is suitable It may be necessary to log site wind speed and direction data at various heights prior to installing the machine Any indication of turbulence means that the generator should be re sited or raised above the turb...

Страница 14: ...d and in line with the guys Anchors in soft earth may require concrete blocks or dead men Gravel or clay soils require auger type anchors see inset picture and rocky ground may need drilling and expanding rock anchors Only the eye should be visible above ground Avoid waterlogged soils which have poor holding properties Install anchor below the frost level or otherwise frost heave will eject them B...

Страница 15: ...ould diminish this clearance The pole base should be mounted where the structure is very rigid 4 5 4 Mechanical installation of Pacific 300 stern mount kit a Check Ensure that a complete and undamaged set of parts has been received b Pole position The pole base fixing may be moved to one side provided that when viewed from above the angle between the strut and either wire is greater than 45 degree...

Страница 16: ...s so as not to crush the mast If there is any danger of running rigging becoming entangled in the wind turbine then install stays to keep the turbine guarded 4 6 Electrical installation Electrical installation should only be performed by competent personnel who have studied this manual If in doubt ask Ampair First mechanically mount the main system components except the wind turbine then run the f...

Страница 17: ...se sizing 30 A for 12 V 15 A for 24 V stop switch rectifier rectifier or integrated rectifier regulator such as the S 12 300 and S 24 300 Connection diagram rectifier or integrated regulator rectifier battery rectifier fuse stop switch ammeter DC colour code Red positive Black negative Fuse sizing 30 A for 12 V 15 A for 24 V regulator Block diagram Ideally connect the ammeter between the rectifier...

Страница 18: ...ulator such as NC25A used in single in single out configuration Connection diagram separate regulator and rectifier ammeter bat regulator in sense sense battery fuse DC colour code Red positive Black negative Fuse sizing 30 A for 12 V 15A for 24 V stop switch rectifier heat sink separate rectifier and regulator such as PR 300 used in single in single out configuration Connection diagram separate r...

Страница 19: ...th Up to 5 m Up to 16 ft 5 to 10 m 16 to 32 ft 10 to 18 m 32 to 60 ft 18 to 28 m 60 to 90 ft 28 to 44 m 90 to 145 ft 44 to 68 m 145 to 220 ft 68 to 110 m 220 to 360 ft Minimum cross sectional area per cable 4 mm2 12 AWG 6 mm2 10 AWG 10 mm2 8 AWG 16 mm2 6 AWG 25 mm2 4 AWG 35 mm2 2 AWG 50 mm2 1 AWG Minimum AC cable size for 24 volt wind turbine Total AC section length Up to 8 m Up to 27 ft 8 to 12 m...

Страница 20: ...he cable runs and mark line ends with a positive and negative symbol to minimise risk of errors At different times and in different countries the colour schemes used in wiring systems have varied If reusing old cable runs the only way to be sure is to carefully trace all the cables and loop test them yourself during initial installation 4 7 2 Fuses and circuit breakers Fuses or miniature circuit b...

Страница 21: ...er is fitted It does not apply if sense wires are used WARNING Never connect an ammeter across the supply 4 7 5 Rectifiers The purpose of a rectifier is to convert the three phase alternating current AC of the turbine to direct current DC that is useful to the battery The rectifier may either be incorporated within the regulator or mounted separately The advantage of incorporating it in the regula...

Страница 22: ...e carriers may be used they protect your system from excessive battery currents in the event of a serious electrical fault If they keep blowing find out why The external fuses must be near to the battery terminals since in the event of a fault the batteries would source the fault current Check and double check polarities before making connections insert the fuses in the fuse carriers last of all A...

Страница 23: ...ON The blades are very sharp Safety gloves must be worn when handling blades The outline process is 1 Item checking 2 Blade mounting 3 Further steps 4 8 1 Item checking The following items will be used during the assembly process Check all are present before starting 1 pcs Generator Hub 3 pcs Rotor blade 1 pcs Blade mounting bolt kit The blade mounting bolt kit includes 6 pcs Blade mounting bolt M...

Страница 24: ...p switch to stop Put blades on blade pitching shafts in order to get all yellow labels indicating the front side of the blade turned towards the top Check and double check that the front side of the blade will be upwind and the back side of the blade will be downwind see Photo 2 The front is the flatter side of the blade and the back is the more curved side of the blade Insert one bolt and one was...

Страница 25: ...ry as shown in the electrical section Insert the fuse or fuses in their carriers 5 OPERATION PERFORMANCE 5 1 Starting and stopping Starting up It is assumed that the wind turbine has been assembled and installed as above If so then remove any ropes that prevent it swivelling or the blades rotating stand well clear and turn the parking stop switch to OFF or 0 Provided there is sufficient wind and t...

Страница 26: ...ewtons 16 kg 35lbs at 20 metres per second 40 knots wind speed Power Speed Curves 0 50 100 150 200 250 300 350 0 5 10 15 20 Wind Speed m sec 1 Power Watts 0 400 800 1200 1600 Speed RPM Power RPM Charging Current 0 5 10 15 20 25 30 0 5 10 15 20 Wind Speed m sec 1 Current Amps 0 5 10 15 20 25 30 Current Amps Current 12 volts Current 24 volts Open Circuit Voltage 0 10 20 30 40 50 60 70 0 500 1000 150...

Страница 27: ...sistance which is of the utmost importance in hostile locations such as tropical sunshine and mountain tops The material is however subject to slow degradation due to ultra violet light which increases towards the tropics and with altitude This process is slow and when it becomes apparent as a slight crazing of the blade surface particularly along leading and trailing edges The design of the blade...

Страница 28: ...brushes Uncoil the retaining ring and lift the body over the pivot The exposed slip ring must be protected from the environment if the generator is removed for further servicing When reassembling put silicone grease not petroleum grease or jelly around the shaft where it passes through the lower bearing Slide the bearing and V seal down the shaft about 20mm and wipe grease around the shaft Slide t...

Страница 29: ...in body Do this very carefully as it must be withdrawn true or it will jam on the stator The shaft and bearings are located using Loctite anaerobic adhesives so some force may be necessary to part them A puller may have to be improvised to do this This job should therefore be done on a suitable work bench The rear bearing needs a bearing puller to remove it if no puller is available a dummy shaft ...

Страница 30: ...11 Ampair 300 Mk1 Pacific Wind Turbine Manual CD 2300 Issue 1 2 Page 30 of 34 30 Ampair April 2007 causes the loss of stator winding insulation due to salt corrosion resulting in electrical leakage and shorted turns ...

Страница 31: ...Date 02 Feb 2011 Ampair 300 Mk1 Pacific Wind Turbine Manual CD 2300 Issue 1 2 Page 31 of 34 31 Ampair April 2007 6 2 Drawings and component list 6 2 1 Exploded drawing ...

Страница 32: ...ETL00002 Pivot lower plain bearing ORG59IX533 Lower plain bearing O ring SPRG00002 Spiral retaining ring SEAL VA 040 AM SP1030 Pivot shaft V seal METL00021 Pivot shaft CBLSR PG11 Cable gland ASMB00002 Brush holder assembly BRSH00001 AM SP3035 Brush set 3 off SCRM4x8 06SS M4x8 machine screws CSTM00005 Electrical box lid NMETL00006 Insulating washer SCRM4x12 12SS M4x12 self tapping screws METL00025 ...

Страница 33: ...two years from the date of purchase Any faulty part will be replaced free of charge and any faulty workmanship will be rectified free of charge upon prepaid return of a unit to Ampair or any authorised agents The unit will then be returned to the customer and freight charged to the customer This guarantee does not cover mishandling accidental damage or faulty installation Nor can Ampair or its aut...

Страница 34: ...ific Wind Turbine Manual CD 2300 Issue 1 2 Page 34 of 34 34 Ampair April 2007 300 complies with the WEE and RoHS directives The packaging materials are only cardboard Expanded foams have deliberately not been used as a packaging material ...

Отзывы: