Professional,
Creditable,
Successful
DMT10768T097-31WT User Guide
11
Step 4
: After finishing the calibration, the system will automatically return to the picture before the calibration.
Note: applies only to a resistive touch panel
3.12 Serial Testing
Test the communication between the Android product and the computer:
Step 1
: Connect the UART0 of Android to the user's computer via a serial cable;
Step 2
: Open “
Android Serial Port Tool
” with COM0 selected as communication port, The Port 1, 2, 4 on
UART1&2&4 are in accordance with COM1, COM2, and COM4. Then, check on options in baud rate, data, stop,
checksum and click “CLOSE” for activating status of serial port. As shown in PIC 5.
PIC 5
Step 3
: Open serial-debugger
SSCOM32
and check serial number, baud rate, and data in options according to Device
Manager in purpose of staying the same set as
Android Serial Port Tool
;
Step 4
: Write command in
Android Serial Port Tool
to see if corresponded correctly in
SSCOM32
. Oppositely, you are
allowed to have reversed operation which is command composing in SSCOM32 but monitoring if received in
Android
Serial Port Tool
.