![AMP Lighting PetalPro APl-3033-B-BZ Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/amp-lighting/petalpro-apl-3033-b-bz/petalpro-apl-3033-b-bz_installation-and-maintenance-manual_2933989005.webp)
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
4
5
Install Stake
AMP
®
PetalPro Path & Area Light
APL-3033-B-BZ
Determine the desired location
for mounting the luminaire.
Hammer the stake into the
ground until flange of stake is
flush to grade. To avoid damage
to the stake, place a board on
top of the stake while hammer-
ing.
Note: If the ground is hard and
the stake is difficult to install,
make a crosscut in the ground
using a flat shovel.
Board
Ground
Soil
Stake
Install Fixture Body to Stake
Pass supply wires through
the center hole of the stake
and thread the stem onto
the stake. Hand tighten until
snug. Clear away area in
ground and lay supply wires
into wireway slots.
Ground
Stem
Supply Wires
Soil
Stake