AMOT CHALWYN MPX-Series Скачать руководство пользователя страница 4

Hose Adaptor Options

SELECTION

Determine the size and position of the MPX valve to be installed.  Within the various constraints imposed in 

the application, the valve should be as generously sized as possible. Check that the valve can be positioned 

such that the reset lever and, where applicable, the stop button will be easily and safely accessible. For types 

with a remote manual stop, position the valve and select the cable length to give a reasonably straight cable 

run between the MPX valve and the proposed stop button position.

Air Pressure

A clean, dry air supply is required.  An air pressure of approximately 2 bar is required to close the valve.

Maximum air pressure must not exceed 10 bar.

 

  203mm (8”) Bore Valves

 

Adaptor 

 

To Suit Hose Bore

 

Part Number 

 

mm (inches)

 

HAX-807 

 

178  (7)

 

HAX-808 

 

203  (8)

 

  127mm (5”) Bore Valves

 

Adaptor 

 

To Suit Hose Bore

 

Part Number 

 

mm (inches)

 

HAX-501 

 

89  (3 

1

/

2

)

 

HAX-502 

 

92  (3 

5

/

8

)

 

HAX-503 

 

95  (3 

3

/

4

)

 

HAX-504 

 

98  (3 

7

/

8

)

 

HAX-505 

 

102  (4)

 

HAX-506 

 

105  (4 

1

/

8

)

 

HAX-507 

 

108  (4 

1

/

4

)

 

HAX-508 

 

111  (4 

3

/

8

)

 

HAX-509 

 

114  (4 

1

/

2

)

 

HAX-510 

 

117.5  (4 

5

/

8

)

 

HAX-511 

 

121  (4 

3

/

4

)

 

HAX-512 

 

124  (4 

7

/

8

)

 

HAX-513 

 

127  (5)

 

HAX-518 

 

140  (5 

1

/

2

)

 

HAX-523 

 

152  (6)

Select the required length of the manual shut down cable 

from the table .  Alternative lengths may be available on 

request.  Also order push button assembly RBP-100.

Cable options

 for use with “PUSH” button RBP-100  

To suit valves MPX-302, MPX-502, or MPX-802

 

Cable part No. 

Length (meters)

 CLP-100 

1.0

 CLP-150 

1.5

 CLP-200 

2.0

 CLP-300 

3.0

Select the required length of the manual shut down cable 

from the table .  Alternative lengths may e available on 

request.  Also order handle RTD-100.

Cable options

 for use with “PULL” handle RTD-100  

To suit valves MPX-303, MPX-503, or MPX-803

 

Cable part No. 

Length (meters)

 CLD-100 

1.0

 CLD-150 

1.5

 CLD-200 

2.0

 CLD-300 

3.0

If the valve is to be fitted into a hose as opposed to flange mounted, suitable hose adaptors may be selected from the table 

below for ordering with the valve.

 

  76mm (3”) Bore Valves

 

Adaptor 

 

To Suit Hose Bore

 

Part Number 

 

 mm (inches)

 

HAX-320 

 

38    ( 1

1

/

2

)

 HAX-322   44.5 

(1

3

/

4

)

 

HAX-301 

 

51    (2)

 

HAX-302 

 

54    (2 

1

/

8

)

 

HAX-303 

 

57    (2 

1

/

4

)

 

HAX-304 

 

60    (2 

3

/

8

)

 HAX-305   63.5 

(2 

1

/

2

)

 

HAX-306 

 

67    (2 

5

/

8

)

 

HAX-307 

 

70    (2 

3

/

4

)

 

HAX-308 

 

73    (2 

7

/

8

)

 

HAX-309 

 

76    (3)

 

HAX-314 

 

89    (3 

1

/

2

)

 

HAX-319 

 

102  (4)

4

MPX  DIESEL ENGINE SHUTDOWN VALVES 

CE236 (9)

T: +44 (0)1284 715739  

[email protected]

Содержание CHALWYN MPX-Series

Страница 1: ...MPX 303 MPX 310 MPX 500 MPX 501 MPX 502 MPX 503 MPX 510 MPX 800 MPX 801 MPX 802 MPX 803 MPX Series Diesel Engine Shut Down Valves Manual Reset Air Pressure and Manual Closure Options Selection Applica...

Страница 2: ...PX 301 MPX 302 MPX 303 MPX 310 MPX 500 MPX 501 MPX 502 MPX 503 MPX 510 MPX 800 MPX 801 MPX 802 MPX 803 Nominal Bore Diameter 76 3 127 5 203 8 minimum maximum A 190 0 207 0 190 0 223 0 246 0 263 0 246...

Страница 3: ...C2 min C2 max B A 1 8 NPT for connecting air pressure supply Optional Hose Adaptors Reset Lever Stop Button C1 C2 min C2 max B A Valve Types MPX 301 MPX 501 and MPX 801 Air Pressure and Integral Stop...

Страница 4: ...511 121 4 3 4 HAX 512 124 4 7 8 HAX 513 127 5 HAX 518 140 5 1 2 HAX 523 152 6 Select the required length of the manual shut down cable from the table Alternative lengths may be available on request Al...

Страница 5: ...pipework should be used and any gaps kept as short as possible taking into account any relative movement and closed by reinforced hose The possibility of a hose collapse on clo sure of the shut down...

Страница 6: ...n handle and tighten Refit handle locknut and handle Tighten locknut 10 Connect shut down air supply using the 1 4NPT tapping on valve Means must be provided to release any trapped air pressure at the...

Страница 7: ...d support bracket fasteners are securely tightened Check that any intake system hoses between the MPX valve and engine are free from damage and suitable for further service Run engine preferably at or...

Страница 8: ...co uk www chalwyn com A division of Roper Industries Limited UK Western Way Bury St Edmunds Suffolk IP33 3SZ Tel 44 0 1284 715739 Fax 44 0 1284 715747 USA 8824 Fallbrook Drive Houston TX 77064 Tel 1 2...

Отзывы: