AMOT 4103D Скачать руководство пользователя страница 2

Temp. Valve for Static Bearings - Models 4103D/M

Datasheet_4103_Temperature_Valve_FEB18_Rev2

Page 2

Contents

Overview  ........................................................................... 3
Operation  .......................................................................... 3
Typical Application  .............................................................. 3
Installation Design Considerations  ........................................ 4

Spacers  ...................................................................... 5
Adapters  ..................................................................... 5
Thermowells  ................................................................ 5

Valve Characteristics  ........................................................... 6

Installed depth and fuse rod length  ................................. 6

How to Order  ..................................................................... 7

Specification 

 ...................................................................... 8

Dimensions  ........................................................................ 8
Maintenance and Service Parts  ............................................. 9

How to order replacement fuse rod assemblies  ................. 9
Replacement fuse rod assembly model number structure  ... 11

Contact  ............................................................................. 12

A Warning indicates a hazardous situation that, if not avoided, could 

result in death or serious injury to personnel.  The text of the warning 

describes the hazard and details of the precautions that must be 

applied before the step of the procedure is carried out.

Содержание 4103D

Страница 1: ...installing in an AMOT 6721L Well For larger moving bearing applications refer to model 4102 temperature detectors datasheet located at www amot com Key features and benefits Provides early warning of...

Страница 2: ...fuse rod length 6 How to Order 7 Specification 8 Dimensions 8 Maintenance and Service Parts 9 How to order replacement fuse rod assemblies 9 Replacement fuse rod assembly model number structure 11 Con...

Страница 3: ...e sensor which will trip upon temperature rise The valves have a stainless steel body containing a normally closed valve sealed with a Viton ball The temperature sensing portion is a thin film of eute...

Страница 4: ...mbly and the valve ball 7 Installed depths Table 1 on page 6 are available in increments from 1 to 9 and must be held to within 1 16 when the unit is installed To accomplish this setting use one or bo...

Страница 5: ...08 38 1 1 Example 6721L 1 15 Code description Comments Basic model A Basic model A 6721L Stainless steel 3 500 psi 9859L 416 Stainless steel 8 000 psi Thread B X Z Thread B 0 20 UNF NPT 6721L 20 UNF 1...

Страница 6: ...7 15 187 3 7 196 9 7 16 200 0 7 209 6 8 17 212 7 8 222 3 8 18 225 4 8 235 0 9 19 238 1 9 247 7 9 20 250 8 9 260 4 10 Table 2 4103M Code Installed depth and fuse rod length Minimum Maximum mm inches m...

Страница 7: ...A 4103D ONLY K M14 X 2 BSP Tr Basic model A 4103D ONLY UK ONLY L 20 NF BSP Tr M 5 16 24 NF NPT Installed depth fuse rod length code C Installed depth fuse rod length code C For installed depth and fus...

Страница 8: ...teel Sensing material Eutectic alloy Valve ball material Viton or stainless steel Rod body Brass Trip temperature range 79 C 173 C 174 F 343 F Maximum allowable temperature 173 C 343 F Maximum control...

Страница 9: ...mbly Look for cracks in the brass A stable fuse rod assembly moves slightly showing no wear Fuse rod assemblies 5 7 Model 4103D and Model 4103M respectively should be replaced if the crimp section bec...

Страница 10: ...Temp Valve for Static Bearings Models 4103D M Datasheet_4103_Temperature_Valve_FEB18_Rev2 Page 10 Maintenance and Service Parts Continued How to order replacement fuse rod assemblies continued...

Страница 11: ...od length code B For fuse rod lengths available refer to Tables 1 2 on page 6 Type C Type C T Temperature Trip temperature F D Trip temperature F D 174 174 F 79 C 197 197 F 92 C 217 217 F 103 C 228 22...

Страница 12: ...19 Email customer service amot com AMOT UK Western Way Bury St Edmunds Suffolk IP33 3SZ England Tel 44 1284 715739 Fax 44 1284 760256 Email info amot com AMOT Germany Rondenbarg 25 22525 Hamburg Germa...