Cabled UV Biofouling Control - Quick Start Guide
This document is a summary guide for setting up Cabled UV Biofouling Control. Complete details may be found in
the Cabled UV Biofouling Control user manual.
Caution: Cabled UV emits Ultraviolet light. Care should be taken to avoid direct exposure to skin or eyes.
1.
Mount device:
Mount the head of the device within approximately 10 cm (~4 inches) of the target surface.
Be sure to clamp only the clamping surface of the device. Refer to Figure 2 for UV beam spread in seawater.
Figure 1 – Cabled UV placed in proximity to the target surface
Figure 2 - Approximate beam spread in seawater
2.
Align UV module to target surface:
Unthread the blue retaining collar and pull uniformly on the quartz
tube to access and align the UV module. Loosen the setscrew to rotate and align the module. Reinstall in
the reverse order.
Figure 3 – Accessing the UV LED module
Figure 4 - Location of setscrew allowing
rotation and alignment of the module.
Target surface
Device clamping surface
7/64” hex head setscrew
Retaining collar
Quartz tube
UV module
(horizontal shown)
Slide