10.1.4 HANDLE LIGHT BATTERY REPLACEMENT
To replace the batteries for either of the independent lights located at
opposite ends of the handle:
1. Remove the corresponding lid screws with a 3mm hex key.
2. Remove and replace the CR123A battery in each of the battery holders.
3. Use the hex key to tighten the lid screws back into position.
REMOVE
SCREWS
Figure 10.1.4
11.0 TROUBLESHOOTING
11.1 GENERAL
NOTICE
Immediately remove malfunctioning or damaged tools from service. Consult your dealer or
AMKUS Rescue Systems.
ALL SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE TECNICIANS IN OBSERVANCE OF
SAFETY REGULATIONS.
Malfunctions can be divided into two sections:
1. Malfunction of the hydraulic system
2. Malfunctions related to other rescue tool systems
Remedies marked by the letter M require the intervention of the Maintenance Technician.
Remedies marked with the letter O can be performed by the Operator.
11.2 TROUBLESHOOTING THE HYDRAULICS
FAULT
POSSIBLE REASON
POSSIBLE REMEDY
PERFORMED BY
STROKE DOES
NOT BEGIN
Control valve actuator damaged
Replace control valve
M
DISCONTINUOUS
MOTION
Max. pressure valve fault
Consult AMKUS Service
Department
M, O
12.0 PARTS, SERVICE, AND TECHNICAL INFORMATION
Parts, service, and technical information may be obtained from your local AMKUS dealer, or at amkus.com.
13.0 DECOMMISSIONING
When decommissioning any AMKUS Rescue Systems Tool or power supply, follow local regulations. For proper disposal information,
contact your local AMKUS Rescue Systems dealer.