1 )
4 points power supply.
1
2
5
3
4
V+
DC SUPPLY
1
2
3
4
From Sensor
(with phantom supply)
AUX INPUT
+
-
+
-
1
2
3
4
5
6
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
Made in France (Fr)
LAN
GPO1
GPO2
DISPLAY MODEL
SERIAL NUMBER
2 )
6 points removable connector.
AFF rear panel
AFF power
supply
REAR PANEL
Wiring power plug
1
4
V+
Gnd
DC supply : 12 Volts 400 mA
1
+
-
V+
SENSOR
OPTO MOS 2
8
OPTO MOS 1
LAN
GPO1
GPO2
V+
Gnd
4
1
SNA mode
- If AFFseries-2 is connected to a SNA, link 2 and 3 of
this connector.
- Otherwise don’t link 2 and 3.
From CAP 40, CAP65, or CAP90
(with phantom power)
+
-
+
-
AUX input
This is the display that supplies the sensor with
phantom supply.
PS 12V
Sensor
(without phantom power)