
WRTB1
XX
wrtb1xx_g_en_105
18/42
4. Conformity assessment
Providing, that router is correctly used, it complies with the requirements of
Czech governmental decree NV616/2006. The conformity assessment has
been carried out in accordance with harmonized standard EN 50121-3-2:2006.
Tested in accordance
with standard
Type of test
Classification
EN 55011:2009
Industrial, scientific and medical
equipment
– Radio-frequency
disturbance characteristics
– Limits and
methods of measurement
Complies
EN 61000-4-2:2009
Electromagnetic compatibility (EMC)
–
Part 4-2: EMC
– Testing and
measurement techniques
– Indirect
electrostatic discharge immunity test,
contact discharge
±8 kV
EN 61000-4-2:2009
Electromagnetic compatibility (EMC)
–
Part 4-2: EMC
– Testing and
measurement techniques
– Indirect
electrostatic discharge immunity test,
aerial discharge
±16 kV
EN 61000-4-3:2006
Electromagnetic compatibility (EMC)
–
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
800 MHz to 1000 MHz
20 V/m
EN 61000-4-3:2006
Electromagnetic compatibility (EMC)
–
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
1400 MHz to 2100 MHz
10 V/m
EN 61000-4-3:2006
Electromagnetic compatibility (EMC)
–
Part 4-3: Radiated, radio-frequency,
electromagnetic field immunity test,
2100 MHz to 2500 MHz
5 V/m
EN 61000-4-4:2012
Electromagnetic compatibility (EMC)
–
Part 4-4: Testing and measurement
techniques
– Electrical fast transient/burst
immunity test, power supply
±3 kV
EN 61000-4-4:2012
Electromagnetic compatibility (EMC)
–
Part 4-4: Testing and measurement
techniques
– Electrical fast transient/burst
immunity test, input
±2 kV
EN 61000-4-5:2006
Electromagnetic compatibility (EMC)
–
Part 4-5: Testing and measurement
techniques
– Electrostatic discharge
immunity test
±4 kV
EN 61000-4-6:2009
Electromagnetic compatibility (EMC)
–
Part 4-6: Testing and measurement
techniques
– Immunity to conducted
disturbances, induced by radio-frequency
fields
10 V