Battery Maintenance
VrLA (Valve regulated Lead Acid) deep cycle or optional lithium-ion batteries are used for operating your Amigo. They are
maintenance-free and are transportable on aircraft, buses, trains, etc. as there is no danger of spillage.By following the charger and
battery procedures, you can expect extended battery life.
Fasteners Replacement
Use only grade 8 (US) or 12.9 DIn (metric) in all applications. For service and
replacement parts, we recommend Amigo authorized parts.
Microprocessor Controller (MPC)
Do not attempt to service the MPC or related electronic components, as this will void the
warranty.
Circuit Breaker Replacement Instructions
An automatic resetting circuit breaker protects the wiring and battery in the event of a short circuit. If your Amigo stops abruptly,
wait 10 seconds for the circuit breaker to reset. If the breaker does not reset, check for overloads or short circuits.
If you suspect the circuit breaker is defective, use a jumper wire between the two terminals of the breaker.
If the Amigo runs now, replace the circuit breaker.
Battery Replacement
nOTE: replacement battery must meet passenger
and cargo aircraft travel requirements.
• Remove four screws as shown
and remove battery front cover.
• Remove the black wire from each battery.
• lift each battery far enough to expose
the red wire connection and remove it
from each battery.
• Reverse this sequence to install batteries.
NOTE:
Tampering with electrical or
mechanical parts will void warranty.
www.myamigo.com
11
Automatic resetting Circuit Breaker